15W Single Output DC-DC Converter
SD-15 series
Features :
2:1 wide input range
Protections:Short circuit/Over load /voltage
Built-in EMI filter, low ripple noise
100% full load burn-in test
Low cost
High reliability
2 years warranty
SPECIFICATION
MODEL
SD-15C-12
SD-15A-24
SD-15A-05
SD-15B-05
SD-15B-12
SD-15B-24
SD-15C-05
SD-15A-12
12V
SD-15C-24
24V
DC VOLTAGE
5V
0.625A
0 ~ 0.625A
15W
3A
1.25A
RATED CURRENT
0 ~ 1.25A
15W
CURRENT RANGE
0 ~ 3A
RATED POWER
15W
150mVp-p
21.6~26.4VDC
1.0%
OUTPUT
RIPPLE & NOISE (max.) Note.2
VOLTAGE ADJ.RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
100mVp-p
4.75~5.5VDC
2.0%
120mVp-p
10.8~13.2VDC
1.0%
0.2%
0.5%
0.3%
0.2%
0.5%
0.3%
LOAD REGULATION
SETUP, RISE ,HOLD UP TIME
VOLTAGE RANGE
2.5s, 25ms,--- 12VDC/24VDC/48VDC at full load
A: 9.2 ~18VDC
B:18 ~ 36VDC
C:36~72VDC
72%
79%
78%
EFFICIENCY(Typ.)
70%
77%
68%
76%
INPUT
76%
75%
DC CURRENT(Typ.)
1.9A/12VDC
0.9A/24VDC
0.45A/48VDC
105 ~160% rated output power
OVER LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
13.8~ 16.2V
5.75 ~ 6.75V
27.6 ~ 32.4V
OVER VOLTAGE
Protection type : Shut off o/p voltage, clamping by zener diode
¡
-10 ~ +60 (Refer to "Derating Curve")
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min.each along X, Y, Z axes
I/P-O/P:2KVAC I/P-FG:1KVAC O/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022(CISPR22)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
SAFETY &
EMC
(Note 4)
Compliance to EN61000-4-2,3,4,6,8, EN55024, light industry level, criteria A
78*51*28mm (L*W*H)
EMC IMMUNITY
DIMENSION
OTHERS
NOTE
PACKING
0.18kg,60 PCS/11.8kg
1. All parameters NOT specially mentioned are measured at normal input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:SD-15-SPEC 2011-06-15