RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
■
■
■
RSG
■
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de
ELECTRONIC COMPONENTS
Änderungen vorbehalten / subject to change without notice
900~1200W Parallel Type With PFC Function
SCP-1K2 series
Features :
AC 180~260VAC input
PF>0.98@ 230VAC
Protections: Short circuit/ Overload/ Over voltage/ Over temperature
Built in remote sense function
Built-in remote ON-OFF control
Power good signal
With parallel function(N+1)
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
3 years warranty
SPECIFICATION
ORDER NO.
SCP-1K2-05 SCP-1K2-09 SCP-1K2-12 SCP-1K2-15 SCP-1K2-18 SCP-1K2-24 SCP-1K2-36 SCP-1K2-48 SCP-1K2-60
SAFETY MODEL NO.
1K2S-P005 1K2S-P009 1K2S-P012 1K2S-P015 1K2S-P018 1K2S-P024 1K2S-P036 1K2S-P048 1K2S-P060
DC VOLTAGE
5V
9V
12V
15V
18V
24V
36V
48V
60V
RATED CURRENT
200A
133A
100A
80A
66.6A
50A
33.3A
24A
20A
CURRENT RANGE
RATED POWER
0 ~ 200A
1000W
0 ~ 133A
1200W
100mVp-p
0 ~ 100A
1200W
120mVp-p
0 ~ 80A
1200W
150mVp-p
0 ~ 66.6A
1200W
180mVp-p
0 ~ 50A
1200W
240mVp-p
0 ~ 33.3A
1200W
360mVp-p
0 ~ 24A
1152W
480mVp-p
0 ~ 20A
1200W
500mVp-p
OUTPUT
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
3.0% Typical adjustment by potentiometer
20%~100% adjustment by 1~5VDC external control
1.5%
0.5%
1.0%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE REGULATION
0.5%
1.5%
LOAD REGULATION
SETUP, RISE, HOLD TIME
500ms, 50ms, 16ms at full load
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
180 ~ 260VAC
47 ~ 63Hz
260 ~ 370VDC see the derating curve
>0.98 / 230VAC
INPUT
EFFICIENCY (Typ.)
AC CURRENT
80%
82%
84%
85%
86%
89%
89%
90%
90%
10A / 230VAC
60A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.) 3.5mA / 240VAC
105 ~ 140% rated output power
OVER LOAD
Note. 4
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% Follow to output set up point
PROTECTION OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
>100 / measure by heat sink, near transformer
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +65 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
0.04% / (0 ~ 50
)
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950, TUV EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC
Compliance to EN55022 (CISPR22) class A
SAFETY &
EMC
(Note. 5)
Compliance to EN61000-3-2,3
HARMONIC CURRENT
EMS IMMUNITY
POWER GOOD SIGNAL
SPECIAL FUNCTION
COOLING
Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A
Open collector of NPN transistor
DC Voltage Adj., remote sensing, remote control, parallel operation(refer to control terminal instruction manual)
By fan, >20% load or >50 fan on
OTHERS
NOTE
MTBF
37.4K hrs min. MIL-HDBK-217F(25
290*120*132mm (L*W*H)
)
DIMENSION
PACKING
4.5kg; 4pcs /19kg /CARTON
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name: SCP-1K2-SPEC 2006-03-28