Radial Lead Resettable Polymer PTCs
SC135 Series
Description
SC135 Series is designed to protect against short duration
high voltage fault currents (power cross or power induction
surge) typically used in AC110V.
Features
u
0.05-3.5A hold current rating
135VAC operating voltage
u
u
u
Fast time-to- trip
RoHS compliant, Lead-Free and Halogen-Free
Applicable
u
u
u
AC110V over-current protection
Power ports
Customer Premises Equipment(CPE)
Electrical Parameters
Maximum Time
To Trip
Resistance
V max
(Vac)
I max
(A)
P dtyp.
(W)
I hold (A)
I trip (A)
Part Number
Current
Time
R min
R max
R 1max
(A)
(Sec.)
(Ω)
(Ω)
(Ω)
SC135-050
SC135-060
SC135-080
SC135-100
SC135-120
SC135-160
SC135-200
SC135-250
SC135-300
SC135-400
SC135-500
SC135-550
SC135-650
SC135-750
SC135-900
SC135-1000
SC135-1100
SC135-1250
SC135-1350
SC135-1600
SC135-1850
SC135-2000
SC135-2500
SC135-3000
SC135-3500
0.05
0.060.08
0.08
0.10
0.12
0.16
0.20
0.25
0.30
0.40
0.50
0.55
0.65
0.75
0.90
1.00
1.10
1.25
1.35
1.60
1.85
2.00
2.50
3.00
3.50
0.10
0.12
0.16
0.20
0.24
0.32
0.40
0.50
0.60
0.80
1.0
1.1
1.3
1.5
1.8
2.0
2.2
2.5
2.7
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
2.5
3.0
4.0
5.0
6.0
6.0
6.0
6.0
6.0
6.0
7.5
7.5
7.5
7.5
9.0
10.0
11.0
12.5
13.5
16.0
18.5
20.0
20.0
20.0
20.0
0.27
0.30
0.38
0.40
0.46
0.50
0.72
0.90
1.0
1.3
1.6
1.6
1.7
1.8
2.1
2.2
2.4
2.6
2.8
3.2
3.6
0.25
0.30
0.40
0.50
0.60
0.80
1.00
1.25
1.50
2.00
2.50
2.75
3.25
3.75
4.50
5.00
5.50
6.25
6.75
8.00
9.25
10.0
12.5
15.0
17.5
4.0
4.0
4.0
5.0
6.0
7.0
5.0
5.0
5.0
5.0
5.0
5.0
8.0
8.0
8.0
8.0
9.0
10.0
10.0
10.0
10.0
12.0
15.0
15.0
15.0
13.5
10.0
7.5
5.0
4.0
2.2
1.8
1.6
1.2
0.90
0.75
0.60
0.45
0.35
0.30
0.25
0.22
0.18
0.16
0.13
0.11
0.10
0.075
0.060
0.050
27.0
20.0
15.0
10.0
8.0
5.0
4.5
3.6
2.7
36.0
27.0
20.0
13.5
10.8
6.8
6.0
4.8
3.3
2.4
2.0
1.65
1.45
1.00
0.80
0.65
0.55
0.50
0.40
0.36
0.27
0.22
0.20
0.15
0.12
0.10
2.0
1.75
1.2
0.96
0.80
0.66
0.60
0.48
0.43
0.33
0.27
0.24
0.18
0.15
0.12
3.2
3.7
4.0
5.0
6.0
7.0
3.9
4.6
5.3
6.0
I hold= Hold current: maximum current device will pass without tripping in 25°C still air.
I trip= Trip current: minimum current at which the device will trip in 25°C still air.
V max= Maximum voltage device can withstand without damage at rated current (Imax
)
I max= Maximum fault current device can withstand without damage at rated voltage (Vmax
Pdtyp.= Power dissipated from device when in the tripped state at 25°C still air.
R min= Minimum resistance of device in initial (un-soldered) state.
)
R max= Maximum resistance of device in initial (un-soldered) state.
R 1max= Maximum resistance of device at 25°C measured one hour after tripping.
Caution: Operation beyond the specified rating may result in damage and possible arcing and flame.
SOCAY Electronics Co., Ltd.
www.socay.com
@ SOCAY Electronics Co., Ltd. 2013
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
Revision September 12, 2013