Octane & G24 ADSL Annex A/C/H
Conexant
S560-6600-JA
•
•
•
•
Designed to meet the requirements of UL1950 and
EN60950 basic insulation with 250 VAC working voltage
•
•
•
Operating and storage temperature range: -40° to +85° C
Meets IEC 695, 2-2 flammability requirements
UL file number E169987, BABT certificate number
NC011559, CB certificate number 14210
PWB Process Capability: standard printed wiring board
assembly techniques, total-immersion cleaning
Minimum interwinding breakdown voltage of 1875 Vrms
for 1 minute between line and IC
•
•
Reliability testing: shock, vibration, temperature cycling,
temperature - humidity - bias
Minimum interwinding breakdown voltage of 600 Vrms
for 1 minute between pins 1 and 2
All specifcations must be met for any DC unbalance
current up to 100mA max in the line side
ELECTRICAL SPECIFICATIONS AT 25° C
Turns
Ratio
±2%
Leakage
DCR
Ω
max
Interwinding Longitudinal
Harmonic
Distortion4
dB max
Inductance1
µH ±6.7%
Inductance2
µH
Capacitance3
pF max
Balance4
dB max
Part Number
IC
Side
Line
Side
20kHz -
2.2MHz
12Vpp
150kHz
Line : IC
(1 - 4)
(1 - 4)
Line : IC
S560-6600-JA
0.95 : 1
750
6 -10
1.5
1.5
20
-45
-85
All measurements are made with pin 2 connected to pin 3 and pin 5 connected to pin 7 except for breakdown
voltage between pin 1 and 2.
1. Inductance measured at 10 kHz, 0.1 Vac
2. Leakage inductance measured at 100 kHz, 0.1 Vac
3. Interwinding capacitance measured at 10 kHz, 1.0 Vac
4. Measured with line impedance of 100 Ω and IC impedance of 110.8 Ω
SCHEMATIC
S560-6600-JA
8
1
3
5
7
IC
LINE
2
4
6
©2004 Bel Fuse Inc. Specifications subject to change without notice. 12.04
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
page 1