2) 2 coil latching
Nominal operating
current [ 10%]
(at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Coil resistance [ 10%]
Max. applied
voltage
(at 40°C 104°F)
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
(at 20°C 68°F)
Type
Set coil
66.7mA
38.5mA
33.7mA
16.7mA
8.4mA
Reset coil
66.7mA
38.5mA
33.7mA
16.7mA
8.4mA
Set coil
45Ω
Reset coil
45Ω
Set coil
200mW
192mW
200mW
200mW
202mW
355mW
Reset coil
200mW
192mW
200mW
200mW
202mW
355mW
3V DC
5V DC
5.5V DC
9.0V DC
130Ω
130Ω
70%V or less of
nominal voltage
(Initial)
70%V or less of
nominal voltage
(Initial)
6V DC
180Ω
180Ω
11.0V DC
22.0V DC
44.0V DC
65.0V DC
Standard
12V DC
24V DC
48V DC
720Ω
720Ω
2,850Ω
6,500Ω
2,850Ω
6,500Ω
7.4mA
7.4mA
2. Specifications
Characteristics
Item
Specifications
Arrangement
Contact resistance (Initial)
2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A
Max. 50 mΩ (By voltage drop 6 V DC 1A)
Approx. 3pF
Electrostatic capacitance (initial)
Contact material
Contact
Rating
Au clad Ag alloy (Cd free)
Thermal electromotive force (at nominal coil voltage)
(initial)
Approx. 3μV
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
4 A 250 V AC, 3 A 30 V DC
1,000 VA, 90 W
250 V AC, 48 V DC (30 to 48 V DC at less than 0.5 A)
4 A (AC), 3 A (DC)
Max. switching current
Min. switching capacity (Reference value)*1
100μA 100 m V DC
Min. 10,000MΩ (at 500V DC)
Measurement at same location as “Breakdown voltage” section.
Insulation resistance (Initial)
Between open contacts
750 Vrms for 1min. (Detection current: 10mA.)
Breakdown voltage
Between contact sets
(Initial)
1,000 Vrms for 1min. (Detection current: 10mA.)
1,500 Vrms for 1min. (Detection current: 10mA.)
Electrical
characteristics
Between contact and coil
Operate time [Set time] (at 20°C 68°F)
Max. 15 ms [15 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 10 ms [15 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Release time [Reset time] (at 20°C 68°F)
Functional
Shock resistance
Min. 490 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 4 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Expected life
Conditions
Unit weight
Mechanical
Min. 108 (at 50 cps)
Ambient temperature: –55°C to +65°C –67°F to +149°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions for operation, transport and storage*2
Approx. 8 g .28 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3. Electrical life
Condition: Resistive load, at 20 times/min.
Types
Switching capacity
4A 250 V DC
3A 30V DC
No. of operations
Min. 1×105
Min. 2×105
2 Form A 2Form B, 3 Form A 1 Form B, 4 Form A
ASCTB207E 201701-T