35W Single Output Switching Power Supply
S-35 series
Features :
AC input range selected by switch
Protections:Short circuit/Over load
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 37KHz
1 year warranty
SPECIFICATION
MODEL
S-35-5
S-35-12
S-35-15
S-35-24
DC VOLTAGE
5V
12V
15V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
7A
3A
2.4A
1.5A
0 ~ 7A
35W
0 ~ 3A
36W
0 ~ 2.4A
36W
0 ~ 1.5A
36W
RIPPLE & NOISE (max.) Note.2 75mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
100mVp-p
100mVp-p
100mVp-p
22.6 ~ 26.4V
1.0%
OUTPUT
4.75 ~ 5.5V
10.8 ~ 13.2V
1.0%
13.5 ~ 16.5V
1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
200ms, 100ms, 30ms at full load
85 ~ 132VAC / 170 ~ 264VAC selected by switch
47 ~ 63Hz
240 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY(Typ.)
70%
76%
78%
78%
INPUT
AC CURRENT
0.8A/115VAC
0.45A/230VAC
INRUSH CURRENT(max.)
LEAKAGE CURRENT
COLD START 18A/115VAC
<2mA / 240VAC
36A/230VAC
105 ~ 150% rated output power
OVER LOAD
PROTECTION
ENVIRONMENT
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1012
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY &
EMC
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Design refer to FCC Part15 J Conduction Class B
MTBF
435.2K hrs min. MIL-HDBK-217F (25
129*98*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.41Kg; 30pcs/13.4Kg/0.86CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:S-35-SPEC 2004-06-30