210W Single Output Switching Power Supply
S-210 series
■ Features :
$AC input range selectable by switch
$Protections: Short circuit / Overload / Over voltage / Over temperature
$100% full load burn-in test
$Fixed switching frequency at 90KHz
$Low cost
$High reliability
$2 years warranty
SPECIFICATION
MODEL
S-210-5
S-210-7.5
S-210-12
S-210-13.5
S-210-15
S-210-24
S-210-27
S-210-48
DC VOLTAGE
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
40A
27A
17A
15A
14A
8.8A
7.8A
4.4A
0 ~ 40A
200W
0 ~ 27A
202.5W
100mVp-p
6 ~ 9V
2.0%
0 ~ 17A
204W
0 ~ 15A
202.5W
120mVp-p
12 ~ 15V
1.0%
0 ~ 14A
210W
0 ~ 8.8A
211.2W
200mVp-p
20 ~ 26.4V
1.0%
0 ~ 7.8A
210.6W
200mVp-p
26 ~ 29V
1.0%
0 ~ 4.4A
211.2W
200mVp-p
45.6 ~ 52.8V
1.0%
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
120mVp-p
10 ~ 13.2V
1.0%
120mVp-p
13.5 ~ 18V
1.0%
OUTPUT
4.5 ~ 5.7V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1000ms, 20ms/230VAC
1000ms, 20ms/115VAC at full load
20ms/230VAC 20ms/115VAC at full load
VOLTAGE RANGE
88 ~ 132VAC / 176~264VAC by switch
47 ~ 63Hz
248 ~ 370VDC
84%
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
79%
82%
2.5A/230VAC
50A/230VAC
83%
85%
87%
87%
87%
INPUT
4.2A/115VAC
35A/115VAC
<3.5mA / 240VAC
LEAKAGE CURRENT
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 31.05 ~ 36.45V 55.2 ~ 64.8V
OVERLOAD
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
RTH1≧85℃
OVER TEMPERATURE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +50℃ (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT
0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
ISOLATION RESISTANCE
MTBF
244.7K hrs min. MIL-HDBK-217F (25℃)
215*115*50mm (L*W*H)
OTHERS
NOTE
DIMENSION
0.95Kg; 12pcs/12.4Kg/0.92CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:S-210-SPEC 2007-10-25