150W Single Output Switching Power Supply
RS-150 series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High realibility
SPECIFICATION
MODEL
RS-150-3.3
RS-150-5
RS-150-12
RS-150-15
RS-150-24
RS-150-48
DC VOLTAGE
3.3V
5V
12V
15V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
30A
26A
12.5A
10A
6.5A
3.3A
0 ~ 30A
99W
0 ~ 26A
130W
80mVp-p
4.75 ~ 5.5V
2.0%
0 ~ 12.5A
150W
0 ~ 10A
150W
0 ~ 6.5A
156W
0 ~ 3.3A
158.4W
200mVp-p
45.6 ~ 52.8V
1.0%
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 3.0%
120mVp-p
11.4 ~ 13.2V
1.0%
120mVp-p
14.25 ~ 16.5V
1.0%
120mVp-p
22.8 ~ 26.4V
1.0%
OUTPUT
3.2V ~ 3.5V
LINE REGULATION
LOAD REGULATION
Note.4
Note.5
0.5%
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
800ms, 20ms, 20ms/230VAC
88 ~ 132VAC / 176 ~ 264VAC selected by switch
47 ~ 63Hz
1200ms, 30ms, 10ms/115VAC at full load
248 ~ 373VDC(300VAC peak 5sec. No damage)
FREQUENCY RANGE
EFFICIENCY(Typ.)
75%
78%
83%
84%
86%
87%
INPUT
AC CURRENT
3A/115VAC
2A/230VAC
INRUSH CURRENT(max.)
COLD START 50A/230VAC
<2mA / 240VAC
LEAKAGE CURRENT
110 ~ 150% rated output power
OVER LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V
PROTECTION
27.6 ~ 32.4V
55.2 ~ 64.8V
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMC
(Note 6)
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A
EMS IMMUNITY
MTBF
244KHrs min. MIL-HDBK-217F (25
199*98*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.7Kg; 20pcs/14Kg/0.72CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:RS-150-SPEC 2004-03-25