5秒后页面跳转
RM3542 PDF预览

RM3542

更新时间: 2022-02-26 14:00:28
品牌 Logo 应用领域
ASM-SENSOR /
页数 文件大小 规格书
8页 2741K
描述
An Evolution in Stable Measurements

RM3542 数据手册

 浏览型号RM3542的Datasheet PDF文件第1页浏览型号RM3542的Datasheet PDF文件第2页浏览型号RM3542的Datasheet PDF文件第3页浏览型号RM3542的Datasheet PDF文件第5页浏览型号RM3542的Datasheet PDF文件第6页浏览型号RM3542的Datasheet PDF文件第7页 
4
RM3542A  
RM3542  
Consistent Reliability  
Shared Features  
Productivity  
Improved  
Perfect for  
Automation  
Reduce Contact Error Rate  
Reliability Improved with Positive Contact  
Contact Improver Function Ensures Quick and  
Reliable Contact  
Contact Checking while Measuring  
Reliable checking and reduced contact time are achieved by  
performing contact checks while measuring, instead of before  
and after, as is traditionally done.  
Contact is improved by penetrating oxidation and impurities  
between probes and samples. Measurements stabilized by  
improving poor contact, and a reduction in the contact error rate,  
lead to improvements in productivity.  
Conventional procedure  
Production  
Probe Bounds  
Contact  
Improved  
Stable  
Measurement  
Not Checked  
Contact Check  
Contact Check  
Volume  
Increased  
17 mA, 25 mA, 35 mA (default value), 50 mA  
Contact Condition  
Choices for contact improvement current  
:
Measuring  
Contact Condition  
RM3542  
Contact Improver  
Function  
RM3542A  
Probe Bounds Detected  
Contact Condition  
Contact Check  
Checking  
Contact Check  
Measurement  
Measuring  
Measuring  
Contact Time  
Reduced  
Noise  
Resistant  
Monitor Contact Condition  
Detect Contact Errors  
(Voltage Monitor Function)  
Reduce Measurement Time for More  
Stable Measurements  
Large voltage fluctuations due to changes in current terminal  
contact resistance or noise from mechanical vibrations are  
detected as errors.  
Integration Time Setting Function  
You can set the integration time as desired for each range.  
Set a short integration time to reduce the takt time, or a long  
integration time for more stable inspection.  
Contact Condition  
Detection Voltage  
Default Setting  
LOW POWER: OFF  
Range  
Integration Time  
ERROR  
FAST MED SLOW  
0.5 ms 5.0 ms 1 PLC  
0.3 ms 2.5 ms 1 PLC  
0.5 ms 3.0 ms 1 PLC  
1.5 ms 5.0 ms 1 PLC  
Error  
Takt  
Reduced  
Stable  
Measurement  
100 mΩ  
1000 mΩ  
100 kΩ  
Probe contact chattering  
Probe deterioration  
External noise  
Notification on C.E.Volt display  
Notification by  
outputting a signal  
ERR  
1000 kΩ  
Default  
Setting  
Integration  
Time  
Reduce Contact Error Rate  
Repeat Measurement when an Error Occurs  
(Retry Function)  
Noise-Resistant Floating Structure  
The Retry Function automatically repeats the measurement  
when a fault occurs due to probe chatter.  
The floating structure of the measurement area minimizes any  
effects from nearby noise on the meas
Probe Bounds  
Contact Condition  
Contact Improver  
ON  
OFF  
ON  
ON  
ON  
Function  
Contact Check  
Measurement  
OFF  
OFF  
ON  
定中  
PLC PC  
Retry  

与RM3542相关器件

型号 品牌 描述 获取价格 数据表
RM3542A ASM-SENSOR An Evolution in Stable Measurements

获取价格

RM35HG-34S MITSUBISHI Super Fast Recovery Diodes

获取价格

RM35HG-34S POWEREX Super Fast Recovery Single Diode (35 Amperes/1700 Volts)

获取价格

RM35TF30 SCHNEIDER DPDT, Momentary, 5A (Contact), 250VDC (Contact), AC/DC Output, DIN-Rail Mount

获取价格

RM-3638T EVERLIGHT Logic Output Photo IC, ROHS COMPLIANT, MINIATURE, PLASTIC PACAKGE-3

获取价格

RM36600L2RBL ETC ULTRA-R2 36X600 BLUE RUBBER MAT

获取价格