5秒后页面跳转
RLS40 PDF预览

RLS40

更新时间: 2024-11-10 23:32:55
品牌 Logo 应用领域
其他 - ETC /
页数 文件大小 规格书
1页 388K
描述
Fuse

RLS40 数据手册

  
RLN/RLS Class H Fuses  
250/600 VAC Renewable 1 600 Amperes  
SPECIFICATIONS  
Voltage ratings:AC: 250 Volts (RLN); 600 Volts (RLS)  
Interrupting ratings: AC: 10,000 amperes rms symmetrical  
Ampere range: 1 600 amperes  
Approvals: UL Listed Class H fuses per UL 248  
(formerly UL 198B)  
GENERAL  
PURPOSE  
FUSES  
(File No. E83838)  
CSA Certified per Spec No. 59.1  
(File No. LR29862)  
FUSE LINKS: To order, specify LKN (250V) or LKS (600V)  
plus ampere rating shown below.  
AMPERE RATINGS  
1
2
3
4
5
6
8
10  
12 **  
15  
20  
25  
30  
35  
40  
45  
50  
60  
70  
80  
90  
175  
200  
225 * 450 *  
250 * 500 *  
300 * 600 *  
350 *  
400 *  
100  
110  
125  
150  
*These ampere ratings require two links per fuse.  
**RLS Only.  
Example part number (series & amperage): RLN 20  
RECOMMENDED FUSE BLOCKS  
LH250 series (for RLN series fuses)  
LH600 series (for RLS series fuses)  
Refer to Fuse Block section of this catalog for additional  
information.  
Littelfuse RLN/RLS series renewable fuses are a quality  
product that have traditionally been used to provide low cost  
protection of general purpose feeder and branch circuits  
where available short-circuit currents do not exceed 10,000  
amperes. However, generally increased levels of available  
fault current and the distinct possibility that renewable fuses  
may be improperly renewed, rendering them unsafe, have all  
but eliminated the use of these fuses in new applications. In  
addition, escalating labor costs and increasing automation,  
which makes downtime very expensive, have greatly reduced  
or eliminated the cost savings attributed to renewable fuses.  
COST CONSIDERATIONS  
When comparing the cost of using renewable fuses with the  
cost of other fuses, the labor required for replacing links  
and the cost of additional downtime should be included.  
CAUTIONS  
Renewable fuses should only be used where short circuit  
currents are known to be less than 10,000 amperes, and  
where correct replacement of open links is assured.  
After disassembly of fuse, examine carefully. Discard any  
We recommend the use of POWR-PRO® IDSR series  
Indicatorfuses for circuits between 250 and 600 volts and  
FLNR series for 250 volt and below circuits. Complete  
information on POWR-PRO® Indicator fuses may be found in  
the POWR-PRO® section of this catalog. FLNR fuses are in  
this section of the catalog.  
fuses which show evidence of weakened tube or damaged  
components.  
Remove all link residue from fuse tube.  
Carefully clean all contact surfaces, and remove metal  
spatter from all surfaces.  
Install the proper rated fuse link and tighten all connections  
securely.  
Visually examine fuses for correct alignment of blades.  
DIMENSIONS  
For dimensions, please refer to NLN series for RLN  
dimensions and NLS series for RLS dimensions.  
36  

与RLS40相关器件

型号 品牌 获取价格 描述 数据表
RLS400 LITTELFUSE

获取价格

Electric Fuse, 400A, 600VAC, 10000A (IR), Inline/holder
RLS4148 ROHM

获取价格

Switching diode
RLS4148_1 ROHM

获取价格

Switching diode
RLS4148TE11 ROHM

获取价格

Switching diode
RLS4148TE11A ROHM

获取价格

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon,
RLS4148TE-11A ROHM

获取价格

0.15A, SILICON, SIGNAL DIODE
RLS4148TE11C ROHM

获取价格

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon, LL-34, 2 PIN
RLS4148TE-12 ROHM

获取价格

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon,
RLS4148TE12A ROHM

获取价格

Rectifier Diode, 1 Element, 0.15A, 100V V(RRM), Silicon
RLS4148TE-12A ROHM

获取价格

0.15A, SILICON, SIGNAL DIODE