Max. 444 m3/h
DC centrifugal fans
220 x 56 mm
–
Possible special versions:
(See chapter DC fans - specials)
- Speed signal
–
Material:
Scroll housing: GRP1)
Impeller: GRP1)
Base plate: Sheet steel
- Go / NoGo alarm
–
–
Direction of air flow: Axial: Intake,
Centrifugal: Exhaust
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
Connection:
Via single wires AWG 22, TR 64
48 V model: Flat plug
6.3 x 0.8 mm for ground
conductor
- Analog control input
- Humidity protection
- Degree of protection: IP 54
–
–
Highlights:
Weight:
Smoothly operating 3-phase
fan drive
Backward-curved impeller
1.4 kg
1) Fiberglass-reinforced plastic
Series RG 160 NTD
Nominal data
Type
m3/h
cfm
VDC
24
VDC
Bel(A)
/
Watts
rpm-1
°C
Hours
Hours
59
34.7
181
—
2.0
64
800
¿
¡
Min.
RG 160-28/14 NTD...
16...28
-20...+60
55 000 / 35 000
92 500
Max.
308
7.5
4 200
RG 160-28/14 NTD
RG 160-28/14 NTDH
308
370
181
218
24
24
16...28
16...28
7.5
7.8
64
4 200
5 000
-20...+60
-20...+60
55 000 / 35 000
50 000 / 32 500
92 500
85 000
¡
¬
101
59
34.7
181
—
2.0
59
800
¿
¡
Min.
RG 160-28/18 NTD...
48
48
38...57
36...60
-20...+70
-20...+65
55 000 / 27 500
40 000 / 22 500
92 500
67 500
Max.
308
7.5
4 200
RG 160-28/18 N/2 TDHHP
*
444
261
8.5
159
6 000
√
Subject to change
Models RG 160-28/14 NTD... and RG 160-28/18 NTD... are available in customer-specific, custom-developed variants only.
The figures indicated are technically feasible benchmark values.
The fans can be specially adapted to your application with signal outputs and control inputs.
*The specific service life is valid when an external capacitor is wired between the positive and negative wires.
Please note the wiring suggestion.
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L A ISO 103002
W
measured on a hemisphere with a radius of 2 m.
Sound pressure level L A measured at 1 m distance from
p
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
105