65W Triple Output Switching Power Supply
PT-65 series
Features :
Universal AC input/Full range
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
SPECIFICATION
MODEL
PT-65A
PT-65B
PT-65C
PT-65D
OUTPUT NUMBER
CH1
5V
CH2
12V
2.5A
CH3
-5V
CH1
5V
CH2
12V
2.5A
CH3
-12V
0.5A
CH1
5V
CH2
15V
2A
CH3
-15V
0.5A
CH1
5V
CH2
12V
2A
CH3
24V
1A
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
5.5A
0.5A
5.5A
5.5A
4A
0.4 ~ 7A 0.2 ~ 3.2A 0 ~ 0.7A 0.4 ~ 7A 0.2 ~ 3.2A 0 ~ 0.7A 0.4 ~ 7A 0.2 ~ 2.6A 0 ~ 0.7A 0.5 ~ 5A 0.2 ~ 4A 0.2 ~ 1.3A
60W 63.5W 65W 68W
Rated output power for convection; 72W with 18CFM min. Forced air
OUTPUT POWER (max.)
OUTPUT
RIPPLE & NOISE (max.) Note.2 50mVp-p 120mVp-p 50mVp-p 50mVp-p 120mVp-p 100mVp-p 50mVp-p 120mVp-p 100mVp-p 50mVp-p 100mVp-p 200mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 4.0%
CH1:4.75 ~ 5.5V
7.0%
2.0%
4.0%
5.0%
1.0%
1.0%
4.0%
1.0%
3.0%
7.0%
2.0%
4.0%
5.0%
1.0%
1.0%
4.0%
1.0%
3.0%
7.0%
2.0%
4.0%
5.0%
1.0%
1.0%
4.0%
1.0%
2.0%
6.0%
2.0%
5.0%
6.0%
3.0%
5.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
1.0%
3.0%
800ms, 20ms at full load
60ms at full load
90 ~ 264VAC
47 ~ 440Hz
76%
127 ~370VDC
FREQUENCY RANGE
EFFICIENCY(Typ.)
77%
77%
79%
INPUT
1.5A/115VAC
0.9A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
COLD START 20A/115VAC
<0.75mA
40A/230VAC
LEAKAGE CURRENT
OVERLOAD
73 ~ 95W rated output power
74.8 ~ 98.6W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
5.75 ~ 6.75VDC on CH1
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-10 ~ +60 (Refer to "Derating Curve")
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
0.04%/ (0 ~ 50 ) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min.
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
SAFETY &
ISOLATION RESISTANCE
EMC EMISSION
EMC
(Note 4)
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
277.2K hrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
127*76*42mm (L*W*H)
0.25Kg; 54pcs/15.9Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
File Name:PT-65-SPEC 2011-09-30