PSRL9802OS Series
200 Watt Single Output
N + 1 Parallel Redundancy
AC/DC Switching Power Supply
FEATURES
● 2 Year Warranty
● Optional Top Cover
● N+1 Parallel Redundancy
● AC Input Range Auto-Selectable
● Approved to UL CUL TUV CB and CE
● Power Factor Corrected to EN61000-3-2 Class A
● Compact 1U Height & Power Density: 5.16 Watts/cu in
● Providing Peak Power 600W within 500uS Duty Duration
6.8(L) x 3.8(W) x 1.5(H) inches.
SPECIFICATIONS: PSRL9802OS Series
All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
INPUT SPECIFICATIONS
Input Voltage
90 - 132 / 180 - 264vac, Auto-Selectable.
Input Frequency
47 to 63Hz
Input Current
5 / 2.5A at 115 / 230 VAC.
Inrush Current
Leakage Current
Remote On/Off
Max. 70A @ 230VAC and 35A @ 115VAC; cold start.
1.5mA @ 240VAC.
Designated as REMO on the CN3. Requires a low signal to inhabit output; Hiccough mode.
OUTPUT SPECIFICATIONS
Output Voltage
See Table
Output Power Range
Output Adjustability
Total Regulation
200 Watts max with airflow. (See Notes 3 and 4)
Output user adjustable ±5% minimum.
±1%
See Table
Output Current
Ripple & Noise (peak to peak)
Transient Response
Hold-Up Time
±1%
Output voltage returns to within 1% in less than 2.5ms for a 50% load change, peak does not excess 5%.
20ms min. at 120VAC and 80% of full load.
Turn on-off overshoot < 5% over nominal voltage.
Overshoot
Turn On Delay
PROTECTION
1 second maximum at 120VAC.
Over Voltage Protection
Short Circuit Protection
Over-Temperature Protection
Over Load Protection
Input Circuit Protection
GENERAL SPECIFICATIONS
Switching Frequency
Efficiency
Unit latching down when output exceeds 130% and recycle AC input to reset.
Trip without damage and auto-recovery.
Unit protected of excessive operating ambient 85°C, and automatic recovery.
Fold back mode 110-135%; auto-recovery.
One T5A/250V fuse inserted in primary.
25KHz fixed frequency.
70% for 3.3V, 75% for 5V, 80% for 12V, and 83% min. for other outputs (Measuring at 230VAC and full load).
1500 VAC input line to chassis (10mA cut off current), 3000VAC primary to secondary, and 1500VAC primary
to core. All for 3 sec.
Withstand Voltage
Burn In
PFC
Applying 230VAC for input voltage. Applying full load for this product in 45 ±5°C burn-in room for one hour.
Power factor correction pass EN61000-3-2 Class A (total parallel output power not exceed 200W).
Designated as PG on the CN3 will go high 100-500ms after regulation and goes low 1ms before loss of
Power Good
regulation.
Power Supply On
Grounding Test
Green LED designated as LED1 on the PCB.
Apply 25A from ground pin of the three prong plug to the far most earth. Max. allowable resistance is 0.1 ohm.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797