APPLICABLE STANDARD
UL,C-UL TUV STANDARD (Plan)
Operating
-40 C to +105 C
(Note 1)
-40 ℃ to +60 ℃
Storage
Temperature Range
Rating
(Note 2)
Temperature Range
Current
125A
38sq
Voltage
AC/DC 1500V
Applicable Wire
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT
AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
x x
x x
Marking
ELECTRICAL CHARACTEREISTICS
Contact Resistance
DC 1 A
0.3 mΩ max.
x
-
Insulation Resistance
Voltage Proof
250 V DC
5000 MΩ min.
x
x
-
-
2000 V AC. for 1 min.
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Mating and Unmating Forces Measured by applicable connector at a speed of
Mating force : 49 N max.
Unmating force : 49 N max.
x
x
x
-
-
-
30 mm 3 mm/min.
Mechanical Operation
Vibration
100 times insertions and extraction at speed of 600
times/hour.
① Contact resistance : 0.5 mΩ max.
② No damage, crack and looseness of parts.
Frequency : 10 to 55 Hz, singe amplitude 0.75 mm,
① No electrical discontinuity of 10 μs.
② No damage, crack and looseness of parts.
x
x
-
-
at 5 min/cycle, 10 cycles each in 3 axis directions.
30 cycles in TOTAL.
Shock
490 m/s2 duration of pulse 11 ms at 3 times
for 3 both axial directions.
ENVIRONMENTAL CHARACTERISTICS
Temperature -40 → 105 ℃
Time 30 → 30 min
① Contact resistance : 0.5 mΩ max.
Rapid Change Of
Temperature
x
x
-
-
② Insulation resistance : 1000 MΩ min.
③ No damage, crack and looseness of parts.
Chamber transfer time is 2 to 3 min.
Conduct 5 cycles of above cycles(mated)
and exposed in the room temperature for 1 to 2 hours.
After exposure at temperature 402 C, humidity 90 to
95 ,for 96 h.(mated), exposed at room temperatrure
for 1 to 2 hour.
Humidity Life
① Contact resistance : 0.5 mΩ max.
② Insulation resistance : 1000 MΩ min.
③ No damage, crack and looseness of parts.
After exposure at temperature 1052 C,
humidity for 96 h(mated), exposed at room temperatrure
for 1 to 2 hour.
Heat
① Contact resistance : 0.5 mΩ max.
x -
② Insulation resistance : 1000 MΩ min.
③ No damage, crack and looseness of parts.
① Contact resistance : 0.5 mΩ max.
After exposure at -402 ℃, 96 h.(mated)
Cold
x
x
-
Exposed at room temperatrur for 1 to 2 hour.
② Insulation resistance : 1000 MΩ min.
③ No damage, crack and looseness of parts.
No heavy corrosion that lose function.
After exposure in 35±2C, 5±1% salt water spray for
48±4 h(mated),washed with water,dried at normal
temperature and humidity for 24 hours.
Corrosion Salt Mist
-
(Note 1) Storage temperature range shows storage condition for unused products including packing materials.
Follow the operating temperature range for storage condition after mounting.
(Note 2) The operation temperature includes the temperature rise by current carrying.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
RI.TAKAYASU
AH.KODAMA
TS.ITO
20181016
20181016
20181016
20181016
TS.ITO
Unless otherwise specified, refer to IEC60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-129068-10-00
PS3CS-B-1US(10)
SPECIFICATION SHEET
PART NO.
CODE NO
HIROSE ELECTRIC CO., LTD.
CL236-1075-0-10
1/1
0
△
FORM HD0011-2-1