MITMSUITBSIUSBHISSHEIMSIECMOINCDOUNCDTUOCRTO<RAp<pAlipcpaltiicoantiSopneScpifeicciIfnicteIlnlitgeellnigtePnotwPeorwMeordMuoled>ule>
PS11PS01113013
FLAFTL-BATA-SBEASTEYPTEYPE
INSIUNLSAUTLEADTETDYPTEYPE
PS11013
INTEGRATED FUNCTIONS AND FEATURES
• Converter bridge for 3 phase AC-to-DC power conversion.
• Circuit for dynamic braking of motor regenerative energy.
• 3-phase IGBT inverter bridge configured by the latest 3rd.
generation IGBT and diode technology.
• Inverter output current capability IO (Note 1):
Type Name
PS11013
100% load
3.0A (rms)
150% over load
4.5A (rms), 1min
(Note 1) : The inverter output current is assumed to be sinu-
soidal and the peak current value of each of the
above loading cases is defined as : IOP = IO × √2
INTEGRATED DRIVE, PROTECTION AND SYSTEM CONTROL FUNCTIONS:
• For inverter side upper-leg IGBTs : Drive circuit, High voltage isolated high-speed level shifting, Short circuit protection (SC).
Bootstrap circuit supply scheme (single drive power supply) and Under voltage protection (UV).
• For inverter side lower-leg IGBTs : Drive circuit, Short circuit protection (SC).
Control supply circuit under- & over- voltage protection (OV/UV).
System over temperature protection (OT). Fault output signaling circuit (FO) and Current limit warn-
ing signal output (CL).
• For Brake circuit IGBT : Drive circuit
• Warning and Fault signaling :
FO1 : Short circuit protection for lower-leg IGBTs and Input interlocking against spurious arm shoot-through.
FO2 : N-side control supply abnormality locking (OV/UV).
FO3 : System over-temperature protection (OT).
CL :Warning for inverter current overload condition
• For system feedback control : Analogue signal feedback reproducing actual inverter output phase currents (3φ).
• Input Interface : 5V CMOS/TTL compatible, Schmitt trigger input, and Arm-Shoot-Through interlock protection.
APPLICATION
Acoustic noise-less 0.4kW/AC200V class 3 phase inverter and other motor control applica-
tions
PACKAGE OUTLINES
4-R2
0.5
Terminals Assignment:
✽
6
1
2
3
4
5
6
7
8
9
CBU+
CBU–
CBV+
CBV–
CBW+
CBW–
GND
21 VN
22 WN
23 Br
12 3 4 5 6 7 8 910 11121314151617181920212223
2
± 0.3
24
2 4 2 4
NC
VDH
10 CL
11 FO1
12 FO2
13 FO3
14 CU
15 CV
16 CW
17 UP
18 VP
19 WP
20 UN
2
31
32
33
34 P1
35 P2
36
37
38
39
40
R
S
T
2-φ4
2-R4
N
B
U
V
4.14
5.08 ± 0.3 ✕ 9 = 45.72 ± 0.8
31
32 33 34 35 36 37 38 39 40
W
1.2
✽ Control Pin top
✽ Main terminal top
portion details
portion details
± 0.5
0
0.8
0.3
LABEL
54 ± 0.5
62 ± 1
0.35MAX
0.6
± 0.5
0
12
0.5 ± 0.03
(Fig. 1)
Jan. 2000