60W Single Output Industrial DIN Rail Power Supply
PS-60 Series
F eatures :
Univers al A C i nput/F ull range
P rotections :S hort circuit/Over load/Over voltage
C ooling by free a ir c onvection
C an be i ns talled on D IN rail T S -35/7.5 o r 1 5
UL 5 08(indus trial c ontrol e quipment)approved
Is olation c las s
LE D i ndicator for power on
100% f ull load burn-in tes t
3 y ears w arranty
SPECIFICATION
MODEL
PS-6005
PS-6012
PS-6015
PS-6024
DC VOLTAGE
5V
12V
15V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
6.5A
4.5A
4A
2.5A
0 ~ 6.5A
32.5W
0 ~ 4.5A
54W
0 ~ 4A
60W
0 ~ 2.5A
60W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
120mVp-p
11.1 ~ 13.2V
1.0%
120mVp-p
13.5 ~ 16.5V
1.0%
150mVp-p
21.6 ~ 26.4V
1.0%
OUTPUT
LINE R EGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE R ANGE
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
100ms, 30ms, 50ms/230VAC
2 00ms, 30ms, 18ms/115VAC at full load
88 ~ 264VAC
1 24 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
47 ~ 63Hz
INPUT
76%
82%
83%
84%
1.2A/115V AC 0.8A/230V AC
INRUSH CURRENT (max.)
COLD START 18A/115V AC 36A/230V AC
105 ~ 160% rated output power
OVER LOAD
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V
PROTECTION
27.6 ~ 32.4V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, Design refer to EN50178, EN60950-1
I/P-O/P:3KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
SAFETY &
I/P-O/P:100M Ohms/500VDC
Compliance to EN55011,EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMC
(Note 4)
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3 Heavy industry level, criteria A
MTBF
216.2K hrs min. MIL-HDBK-217F (25
78*93*56mm (W*H*D)
)
OTHERS
NOTE
DIMENSION
0.3Kg; 48pcs/15.4Kg/1.02CUFT
PACKING
1. A ll parameters N OT s pecially mentioned are measured at 230VAC i nput, rated load and 25 of ambient temperature.
2. R ipple & n oise a re measured at 20MHz of bandwidth by using a 1 2" twisted pair-wire terminated with a 0 .1uf & 4 7uf parallel capacitor.
3. T olerance : i ncludes s et up tolerance, line regulation and load regulation.
4. T he power s upply is c onsidered a c omponent which will be installed into a f inal equipment. T he final equipment must be re-confirmed that it still meets
E MC d irectives.