Digilent PmodIA™ Impedance Analyzer Reference Manual

PMODIA_RM 数据手册

 浏览型号PMODIA_RM的Datasheet PDF文件第2页浏览型号PMODIA_RM的Datasheet PDF文件第3页 
Digilent PmodIA™ Impedance  
Analyzer Reference Manual  
1300 Henley Court | Pullman, WA 99163  
(509) 334 6306 Voice and Fax  
Revision: November 01, 2012  
Note: This document applies to REV A of the board  
Overview  
The PmodIA is an impedance analyzer built  
around the Analog Devices AD5933  
Impedance Converter Network Analyzer.  
Features include:  
I2C communication interface  
capable of measuring impedances  
ranging from 100to 10 M.  
programmable frequency sweep: start  
frequency, step increment, and number  
of steps.  
clock (SCL) respectively on the PmodIA. (See  
Table 1.) The following instructions explain  
how to read and write to the device.  
programmable gain amplifier  
external clock generation optional  
You must consider two protocols when writing  
to the PmodIA: the write byte/command byte  
and the block write. Writing a single byte from  
the master to the slave requires the master to  
initiate a start condition and send the 7-bit  
slave address. You must hold the read/write bit  
low to write to the slave device successfully.  
The PmodIA should set the slave address as  
0001101 (0x0D) upon startup. After the slave  
acknowledges it’s address, the master must  
send the address of the register it wants to  
write to. Once the slave acknowledges receipt  
of this address, the master will send a single  
data byte that the slave should acknowledge  
with a return bit. The master should then issue  
a stop condition.  
Functional Description  
The PmodIA uses an 8-pin connector that  
allows for I2C communication. There is also a  
1-pin connector that allows you to select either  
a high or low impedance measurement.  
The PmodIA measures impedance by emitting  
an AC voltage at a known frequency and  
sampling the frequency response to identify  
the unknown impedance value. You can  
access the voltage output via the SMA  
connector J3. SMA connector J4 captures the  
response.  
Please see the AD5933 data sheet, available  
from www.analog.com, for more detailed  
information on controlling the analyzer.  
You can also use this protocol to set a pointer  
for a register address. After the master sends  
the slave address and write bit, and the slave  
responds with an acknowledge bit, the master  
sends a pointer command byte (10110000, or,  
0xB0). The slave will assert an acknowledge  
bit and then the master will send the address  
of the register to point to in memory. The next  
time the device reads from or writes data to a  
register, it will occur at this address.  
I2C Interface  
The PmodIA acts as a slave device using I2C  
communication protocol. The I2C interface  
standard uses two signal lines. These are I2C  
data and I2C clock. These signals map to the  
serial data (SDA) and serial  
Doc: 502-246  
page 1 of 3  
Copyright Digilent, Inc. All rights reserved. Other product and company names mentioned may be trademarks of their respective owners.  

与PMODIA_RM相关器件

型号 品牌 获取价格 描述 数据表
PMODJSTK ETC

获取价格

The PmodJSTK was designed to be a versatile user interface that can be used in a wide vari
PMODLS1 ETC

获取价格

Infrared Light Detector Module Reference Manual
PMODOD1 ETC

获取价格

Digilent PmodOD1™ Open Drain Output Module
PMODOLED_RM ETC

获取价格

PmodOLED™ Reference Manuall
PMODPMON1 ETC

获取价格

PmodPMON1™ Refference Manuall
PMODR2R ETC

获取价格

The PmodR2R board provides digital-to-analog conversion using a circuit that has been a st
PMODRJ45 ETC

获取价格

PmodRJ45™ Connector Modules Reference Manua
PMODSD_RM ETC

获取价格

The PmodSD Secure Digital memory card module provides a convenient SD card slot for use wi
PMODTMP2 ETC

获取价格

PmodTMP2™ Reference Manuall
PMODTPH ETC

获取价格

Digilent PmodTPH Test Point Header Board Reference Manual