S p e c i f i c a t i o n s
MODELS
ITEMS
PM10
PM20
PM30
DC Input
Input Line Transients (100ms max)
VDC
-
12V: 9-18V, 24V: 18-36V, 48V; 36-75V
12V input: 25V, 24V input models 50V
48V input: 100V ETSI Standard ETS 300132 (100V 10 joules)
0.4W
No Load Input Power
-
-
-
-
-
-
-
-
Inrush Current Limiting
EMI (24V&48V I/P models) (1)
Output Voltage Accuracy
Output Voltage Adj. Range (Trim)
Line Regulation (typical)
Load Regulation (typical) (2)
Minimum Loading
ETSI-300-132 (< 50A peak)
EN55022 B, FCC B, ANSI 63.12-1987
Single output: ± 1%, Dual output: ± 1.5%
None
Output 1: ± 10%
Main 0.2%, Aux 3%
0.2%
Single / main output: 1.0%, Dual: 2%, PM30xxT aux outputs: 8%
A minimum load of 0.1A is required on outputs 2 and 3 in order for the converter to turn-on.
Regulation values pertain to operation with output currents above 10% of rated load
current on main output and above 25% of rated current on auxiliary outputs.
3V & 5V Outputs: 75mV, 12V & 15V Outputs: 100mV(3)
Output is clamped at factory set level
Ripple and Noise (Peak to peak)
Overvoltage Protection
Short Circuit Protection
Cooling
-
-
-
-
Main output: Continuous, Aux outputs: 30ms max
Convection
Operating Temp. Range
Temperature Coefficient
Humidity (non condensing)
Isolation Resistance
Isolation Voltage (Input to output)
Vibration and Shock
Remote On / Off
Safety Agency Approval
Size (L x W x H)
Warranty
-
-
-
-40ºC to + 70ºC
-40ºC to + 60ºC
-40ºC to + 50ºC
Outputs 1 & 2: ± 0.015%/ºC, PM30xxT aux outputs: ± 0.03%/ºC
5% to 95% RH
10M
Ohm
12V & 24V input models: 700VDC, 48V input: 1500VDC
2.5G, 10-50Hz, 10 minutes per axis
None
-
-
-
in
-
Low = OFF
UL, CSA, EN60950 and CE Mark
2x1x0.33
2x1.6x0.33
Two Years
3x2.5x0.33
Note: See Installation Manual for full details, test methods of parameters & app. notes
(1) With external filter
(2) For a 25 to 100% load change, > 5W load on output 1 for PM30xxT
(3) 120mV pk pk on outputs 2 & 3 of triple output PM30
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4