16W Single Output LED Power Supply
PLD-16 series
Features :
115VAC or 230VAC models available
Built-in active PFC function
Constant current design
Protections: Short circuit / Over temperature
Cooling by free air convection
Fully isolated plastic case
Class 2 Power Unit
Class
power unit, no FG
IP30 design
Suitable for indoor LED lighting applications
100% full load burn-in test
Low cost
High reliability
3 years warranty
110
F
SELV
( for A type only)
( for B type only)
( for 350mA)
(except for 350mA)
( for B type only)
( for B type only)
PLD-16-350 A A : With AC input 90~ 135VAC.
B : With AC input 180~ 295VAC.
SPECIFICATION
MODEL
PLD-16-350
PLD-16-700
PLD-16-1050
PLD-16-1400
RATED CURRENT
350mA
700mA
1050mA
1400mA
OPERATING VOLTAGE RANGE 24 ~ 48V
16 ~ 24V
0 ~ 700mA
12 ~ 16V
0 ~ 1050mA
8 ~ 12V
CURRENT RANGE
CURRENT ACCURACY
RATED POWER
0 ~ 350mA
5.0%
0 ~ 1400mA
OUTPUT
16.8W
16.8W
2.7Vp-p
35V
16.8W
2.2Vp-p
25V
16.8W
2Vp-p
16V
RIPPLE & NOISE (max.) Note.1 4.6Vp-p
NO LOAD OUTPUT VOLTAGE (max.) 63V
SETUP TIME
1000ms / 230VAC 2000ms / 115VAC at full load
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR (Typ.)
PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
A series 84.5%
84.5%
84%
85%
82.5%
83.5%
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
86%
86%
B series
0.4A/115VAC 0.2A/230VAC
40A/230VAC
0.15A/277VAC
INRUSH CURRENT(max.)
LEAKAGE CURRENT
SHORT CIRCUIT
<0.5mA / 240VAC
Hiccup mode, recovers automatically after fault condition is removed.
95 10 (RTH1)
PROTECTION
ENVIRONMENT
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
UL 8750,CSA C22.2 No.250.0-08(except for PLD-16-350);ENEC EN 613471-1,EN 61347-2-13 independent(for B type only)approved
I/P-O/P:3.75KVAC
SAFETY &
EMC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015 (B type only), EN61000-3-2 Class C ; EN61000-3-3, FCC part 18 non-consumer equipment(A type only)
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level, criteria A
EMC IMMUNITY
MTBF
906.5Khrs min. MIL-HDBK-217F (25
84*57*29.5mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.19Kg; 72pcs/14.7Kg/0.92CUFT
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLD-16-SPEC 2012-03-16