Ordering information
AC-DC Power Supplies Enclosed Type
PL
A
15
F
-O -O
5 6
PLA15F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-04-472
R
*7
6Optional
C: with Coating
J : Connector interface
T : Vertical terminal block
-NO: with DIN rail
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PLA15F-5
PLA15F-12
PLA15F-15
PLA15F-24
*3
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
ACIN 100V 0.4typ (Io=90%)
VOLTAGE[V]
ACIN 115V 0.4typ (Io=100%)
ACIN 230V 0.25typ (Io=100%)
50 / 60 (47 - 63)
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 72.5typ (Io=90%)
ACIN 115V 73.5typ (Io=100%)
ACIN 230V 75.5typ (Io=100%)
75.5typ (Io=90%)
77.0typ (Io=100%)
78.5typ (Io=100%)
77.0typ (Io=90%)
78.5typ (Io=100%)
79.5typ (Io=100%)
78.0typ (Io=90%)
79.0typ (Io=100%)
80.0typ (Io=100%)
INPUT
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start
ACIN 115V 16typ (Io=100%) Ta=25Cat cold start
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.30max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
5
3
12
15
1
24
1.3
0.7
CURRENT[A]
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
WATTAGE[W]
ACIN 115V-264V 15.0
15.6
15.0
16.8
*
4
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
48max
60max
96max
*
4
100max
120max
160max
240max
150max
180max
300max
120max
150max
48max
120max
120max
160max
240max
150max
180max
300max
150max
180max
60max
150max
120max
160max
280max
150max
180max
320max
240max
290max
96max
0 to +50C 80max
-10 to 0C 140max
Io=0 to 35% 160max
0 to +50C 120max
-10 to 0C 160max
Io=0 to 35% 240max
0 to +50C 50max
-10 to +50C 60max
RIPPLE[mVp-p]
*1
OUTPUT
RIPPLE NOISE[mVp-p] *1
TEMPERATURE REGULATION[mV]
*
2
20max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
200typ (ACIN 115V, Io=100%) *Start-up time is 700 ms typ for less than 1 minute of applying input again from turning off the input voltage.
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50
10.80 to 13.20
12.00 to 12.48
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
5.00 to 5.15
Works over 105% of rating and recovers automatically
13.80 to 16.80
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00
17.25 to 21.00
27.60 to 33.60
PROTECTION
CIRCUIT AND
OTHERS
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
LED (Green)
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
INPUT-FG
ISOLATION
OUTPUT-FG
*
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
8
April17, 2018
PLA-2