PH150S280 Specifications
NEMIC-LAMBDA
* : For delivery, contact to our sales office.
C095-01-01B
MODEL
ITEMS
*
PH150S
280-3.3
3.3
30
99
*
PH150S
280-15
15
10.0
150
*
PH150S
280-28
28
5.4
151.2
88
PH150S
280-5
5
30
150
82
PH150S
280-12
12
12.5
150
PH150S
280-24
24
6.3
151.2
88
1 Nominal Output Voltage
2 Maximum Output Current
3 Nominal Output Power
4 Efficiency (Typ)
V
A
W
%
-
A
A
%
%
mV
mV
mV
-
72
85
85
( 1)
5 Input Voltage Range
200 ~ 400VDC
0.47
0.37
280VDC input
6 Input Current (Typ)
(at full load)
0.65
0.51
0.63
0.49
0.63
0.49
0.61
0.48
0.61
0.48
360VDC input
7
Output Voltage Accuracy
8 Output Voltage Range
( 1)
( 8)
( 9)
( 2)
( 3)
( 4)
( 5)
± 1%
± 10% (At 280VDC input)
9
10
11
12
13
100
20
40
100
20
40
150
48
96
150
60
120
240
96
192
280
112
224
Maximum Ripple & Noise
Maximum Line Regulation
Maximum Load Regulation
Over Current Protection
Over Voltage Protection
105% ~ 150%
165~240% 125% ~ 145%
Possible
-
-
14 Remote Sensing
15 Remote ON/OFF Control
16 Parallel Operation
17 Series Operation
(*8)
-
-
-
-
-
-
-
-
Possible (Short : ON, Open : OFF)
-----
Possible
-20 ~ +85°C (Baseplate) Ambient Temperature min = -20°C
30 ~ 95%RH (No dewdrop)
-40 ~ +85°C
10 ~ 95%RH (No dewdrop)
Conduction Cooled
( 8)
( 6)
19
Operating Temperature
20 Operating Humidity
21 Storage Temperature
22 Storage Humidity
23 Cooling
( 7)
24 Temperature Coefficient
25 Withstand Voltage
-
-
0.02% / °C
Input - Baseplate : 2.5kVAC (20mA) for 1 minute.
Input - Output : 3.0kVAC (20mA) for 1 minute.
Output - Baseplate : 500VDC for 1 minute.
26 Isolation Resistance
27 Vibration
-
-
More than 100MΩ at 25°C and 70%RH Output - Baseplate : 500VDC
At no operating, 10 ~ 55Hz amplitude (sweep for 1minute)
0.825mm constant (Maximum 5G) X,Y,Z 1hour each.
Less than 20G (In Package)
Approved by UL (excluding PH150S280-3.3)
Approved by CSA (excluding PH150S280-3.3)
Approved by BSI (excluding PH150S280-3.3)
150g
28 Shock
29 Safety Standard
-
-
-
-
g
UL1950
CSA234
EN60950
30 Weight (Typ)
31 Size (WxHxD)
mm
72 x 12.7 x 86 (Refer to Outline Drawing)
* Read instruction manual carefully, before using the power supply unit.
Derating Curve
=NOTES=
At 280VDC and maximum output current.
200 ~ 400VDC input, constant load.
1.
2.
3.
4.
5.
6.
100
80
No load ~ Full load, constant input voltage.
Constant current limiting with automatic recovery.
Inverter shut-down method, manual reset.
Ratings - Refer to Derating Curve on the right.
- Load (%) is percent of maximum output current.
Heatsink has to be chosen according to instruction manual.
Refer to instruction manual.
60
40
20
0
7.
8.
9.
External components are needed for operation.
(Refer to basic connection and instruction manual)
85
20 40 60 80 100
-20
0
Baseplate Temperature (°C)