PAH150S48
PAH150S48 Specifications
PAH150S48
ꢀ
MODEL
PAH150S48-2.5 PAH150S48-3.3 PAH150S48-5 PAH150S48-12 PAH150S48-15 PAH150S48-24 PAH150S48-28 PAH150S48-48
ITEMS/UNITS
Voltage Range
Input Efficiency (typ)
Current (typ)
V
%
A
DC36 - 76
(*1)
(*1)
75
2.43
2.5
80
3.01
3.3
84
3.72
5
86
88
28
3.63
3.58
3.64
48
CC-E
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
VDC
A
12
15
10
24
CE-
0
09XX
A
35
30
12.5
150
6.3
5.4
3.2
W
87.5
115.5
151.2
153.6
CE-
10XX
Voltage Setting Accuracy (*1)
%
±1.6
Output Maximum Line Regulation(*4) mV
Maximum Load Regulation(*5) mV
Temperature Coefficient
10
10
24
24
30
30
48
48
56
56
96
96
CE-
3101
0.02%/℃
200
KS
KWS
KWD
Maximum Ripple & Noise (-20 to +100℃) (*3) mVp-p
Maximum Ripple & Noise (-40 to -20℃)(*3) mVp-p
Voltage Adjustable Range(*2)
150
200
240
300
280
350
250
400
250
±10%
+15%, -40%
+10%, -40%
105 - 150%
125 - 145%
±20%
PAE
PAF
PAH
PAQ
PF-A
PFE
PH
Over Current Protection (*6)
120 - 160% 120 - 140%
135 - 155%
Over Voltage Protection (*7)
Inverter shutdown (Option available: Refer to option table)
Shutdown ; Auto-restart when unit cool down
Possible (Connect +S and -S terminals to load)
Negative logic (Option available: Refer to option table)
-
Over Temperature Protection
Function
Remote Sensing
(*10)
Remote ON/OFF Control (*8)
Parallel Operation
Series Operation
Possible
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
℃
℃
%RH
%RH
-40 to +100 (Baseplate) Ambient temperature min = -40℃
-40 to +100 (Baseplate) Ambient temperature min = -40℃
30 - 95 (No dewdrop)
30 - 95 (No dewdrop)
Environment
At no operating, 10 ~ 55Hz amplitude (sweep 1 min)
0.825mm constant (maximum 49.0m/s²) X, Y, Z 1 hr each
196.1 m/s²
Vibration
Shock
PMH
Cooling
(*9)
Conduction cooled
Input - Output : 1.5kVAC, Input - Baseplate : 1.5kVAC (20mA) for 1 min
Output - Baseplate : .500VDC for 1 min
Withstand Voltage
Isolation
Isolation Resistance
More than 100MOHM at 25℃ and 70 %RH, Output - Baseplate : 500 VDC
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1.
80
Standards Safety Standards
Weight
Mechanical
g
Size (W x H x D)
mm
57.9 x 12.7 x 61 ( Refer to outline drawing)
(*1) At 48 VDC, maximum output power and baseplate temperature = +25℃.
(*2) Additional external components have to be connected; Refer to application notes.
(*3) External components are needed; Refer to basical connection drawing.
(*4) 36 - 76 VDC, constant load.
Option table:
Option
ON/OFF Logic
OVP
Negative
(H: OFF, L: ON)
Standard
(*5) No load - full load, constant input voltage.
Shut-down
(ON/OFF control reset or
Manual reset)
(*6) Current limiting with automatic recovery.
Positive
(H: ON, L: OFF)
(*7) CNT reset or manual reset.
/P
/V
(*8) Refer to application notes.
Negative
(H: OFF, L: ON)
(*9) Heatsink has to be chosen according to application notes.
(*10) If remote sensing is not required, connect +S and -S to +V and -V respectively
(Refer to basical connection.)
Auto restart
Positive
(H: ON, L: OFF)
/PV
Example: PAH150S48-5/P represent positive logic & OVP
shut-down
・All specifications are subject to change without notice.