PAH200S48
PAH200S48 Specifications
PAH200S48
ꢀ
MODEL
PAH200S48-12 PAH200S48-15 PAH200S48-24 PAH200S48-28
ITEMS/UNITS
Voltage Range
Input Efficiency (typ)
Current (typ)
V
%
A
DC36 - 76
(*1)
(*1)
85
87
4.91
12
4.92
15
4.82
CC-E
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
VDC
A
24
28
CE-
0
09XX
A
16.7
13.4
8.4
7.2
W
200.4
201.0
201.6
CE-
10XX
Voltage Setting Accuracy (*1)
%
±1.6
Output Maximum Line Regulation(*4) mV
Maximum Load Regulation (*5) mV
Temperature Coefficient
24
24
30
30
48
48
56
56
CE-
3101
0.02%/℃
KS
KWS
KWD
Maximum Ripple & Noise (-20 to +100℃) (*3) mVp-p
Maximum Ripple & Noise (-40 to -20℃)(*3) mVp-p
Voltage Adjustable Range(*2)
200
250
240
300
280
350
+10%, -40%
105 -150%
125 - 145%
PAE
PAF
PAH
PAQ
PF-A
PFE
PH
Over Current Protection (*6)
Over Voltage Protection (*7)
Inverter shutdown (Option available: Refer to option table)
Shutdown ; Auto-restart when unit cool down
Possible (Connect +S and -S terminals to load)
Negative logic (Option available: Refer to option table)
-
Over Temperature Protection
Function
Remote Sensing
(*10)
Remote ON/OFF Control (*8)
Parallel Operation
Series Operation
Possible
Baseplate -40 to +80 : 100% of max. load ; min. Ta = -40
+100 : 90% of max. load
Operating Temperature (*11)
℃
Storage Temperature
Operating Humidity
℃
%RH
%RH
-40 to +100 (Baseplate) Ambient temperature min = -40
30 - 95 (No dewdrop)
Environment Storage Humidity
30 - 95 (No dewdrop)
At no operating, 10 - 55Hz amplitude (sweep 1 min)
0.825mm Constant (maximum 49.0m/s²) X, Y, Z 1 hr each
196.1m/s²
Vibration
PMH
Shock
Cooling
(*9)
Conduction cooled
Input - Output : 1.5kVAC, Input - Baseplate : 1.5kVAC (20mA) for 1 min
Output - Baseplate : .500VDC for 1 min
Withstand Voltage
Isolation
Isolation Resistance
More than 100MOHM at 25℃ and 70 %RH, Output - Baseplate : 500 VDC
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1.
80
Standards Safety Standards
Weight
Mechanical
g
Size (W x H x D)
mm
57.9 x 12.7 x 61 (Refer to outline drawing)
(*1) At 48 VDC, maximum output power and baseplate temperature = +25℃.
(*2) Additional external components have to be connected; Refer to application notes.
(*3) External components are needed; Refer to basical connection drawing.
(*4) 36 ~ 76 VDC, constant load.
Option table:
Option
ON/OFF Logic
OVP
Negative
(H: OFF, L: ON)
Standard
(*5) No load ~ full load, constant input voltage.
Shut-down
(ON/OFF control reset or
manual reset)
(*6) Current limiting with automatic recovery.
Positive
(H: ON, L: OFF)
(*7) CNT reset or manual reset.
/P
/V
(*8) Refer to application notes.
Negative
(H: OFF, L: ON)
(*9) Heatsink has to be chosen according to application notes.
(*10) If remote sensing is not required, connect +S and -S to +V and -V respectively
(Refer to basical connection.)
Auto restart
Positive
(H: ON, L: OFF)
/PV
(*11) Refer to output derating curve.
Example: PAH200S48-5/P represent positive logic & OVP
shut-down
・All specifications are subject to change without notice.