5秒后页面跳转
P35-100SAX PDF预览

P35-100SAX

更新时间: 2022-09-29 18:12:38
品牌 Logo 应用领域
其他 - ETC 输出元件
页数 文件大小 规格书
6页 262K
描述
AC-DC POWER MODULE 100VDC OUTPUT

P35-100SAX 数据手册

 浏览型号P35-100SAX的Datasheet PDF文件第2页浏览型号P35-100SAX的Datasheet PDF文件第3页浏览型号P35-100SAX的Datasheet PDF文件第4页浏览型号P35-100SAX的Datasheet PDF文件第5页浏览型号P35-100SAX的Datasheet PDF文件第6页 
POLYTRON POWER SUPPLIES - P3, P5 Series  
P
LINEAR ENCAPSULATED  
POWER MODULES  
REGULATED 5Vdc-250Vdc  
P.C. CARD OR CHASSIS MOUNTING  
Specifications  
115 Vac, 50 to 400 Hz @ 25°C  
FEATURES  
INPUT  
Voltage Range................................................105-125 Vac, 50-60 Hz  
...........................................................400Hz available  
• UL, CE & CSA  
For Worldwide Input Voltage Options, see Options Available chart on pg. 4  
Approved (All Models)  
OUTPUT  
Voltage Accuracy @ FL for Singles, ................................ ....... 1.0%  
• Regulation Line &  
Load 0.2% to 0.02%  
Line Regulation:  
Load Regulation:  
Single Output..................................... 0.2%  
Single Output..................................... 0.2%  
Temperature Coefficient ............................................. 0.02%/°C typ.  
P.C. Card/Chassis  
Mounting  
GENERAL  
Isolation Resistance...........................................................50MOhms  
Protection.......................................................Short Circuit Protection  
• High Isolation Voltage  
Available  
ENVIRONMENTAL  
Operating Temperature Range........................................-25 to +71°C  
........................-40 to +85°C Optional  
Storage Temperature Range...........................................-25 to +85°C  
Cooling................................................................Free Air Convection  
• Short Circuit  
Protection  
PHYSICAL  
Dimensions..................................................See Chart and Diagrams  
1. Case style ending with letter “T”(Chassis mounted units with terminal barrier strip) are designated  
by the suffix “T” . Case styles A,B,C,D,G and E (PC card mounting) do not require suffixing.  
2. Most competitors pinouts available--contact factory.  
3. For 400HZ, use suffix “04” after model number.  
4. For wide operating temperature range, use “W” suffix after model number.  
• Single, Dual & Triple  
Outputs  
• Finger Safe Terminal  
Available  
P3, P5 Series  

与P35-100SAX相关器件

型号 品牌 描述 获取价格 数据表
P35-100S-FST ETC AC-DC POWER MODULE 100VDC OUTPUT

获取价格

P35-100SQX ETC AC-DC POWER MODULE 100VDC OUTPUT

获取价格

P35-100SX ETC AC-DC POWER MODULE 100VDC OUTPUT

获取价格

P35-100SXA ETC AC-DC POWER MODULE 100VDC OUTPUT

获取价格

P35-100SXE ETC AC-DC POWER MODULE 100VDC OUTPUT

获取价格

P35-12 ETC AC-DC POWER MODULE +/- 12VDC OUT

获取价格