OKL2-T/20-W5 Series
Programmable Output 20-Amp iLGA SMT PoL
DC-DC Converter Series
Voltage Range Graph
Please observe the limits below for voltage input and output ranges. These
limits apply at all output currents (Ta = 25°C).
6
5.5
5
4.5
4
3.5
3
2.5
2
1.5
Vin=2.4V / Vout=1.8V
1
0.5
0
Upper Limit
Lower Limit
0
0.5
1
1.5
2
2.5
3
3.5
4
Output Voltage (V)
Figure 8. Voltage Range Graph
Soldering Guidelines
Recommended Lead-free Solder Reflow Profile
Murata Power Solutions recommends the specifications below when installing these
converters. These specifications vary depending on the solder type. Exceeding these
Peak Temp.
235-260° C
250
specifications may cause damage to the product. Your production environment may differ
200
therefore please thoroughly review these guidelines with your process engineers.
Reflow Solder Operations for surface-mount products (SMT)
For Sn/Ag/Cu based solders:
Reflow Zone
150
Soaking Zone
time above 217° C
45-75 sec
120 sec max
Preheat Temperature
Time over Liquidus
Less than 1 ºC. per second
45 to 75 seconds
100
<1.5° C/sec
High trace = normal upper limit
Low trace = normal lower limit
Preheating Zone
240 sec max
50
0
Maximum Peak Temperature
Cooling Rate
260 ºC.
Less than 3 ºC. per second
For Sn/Pb based solders:
Preheat Temperature
Time over Liquidus
0
30
60
90
120
150
Time (sec)
180
210
240
270
300
Less than 1 ºC. per second
60 to 75 seconds
CAUTION: Do not reflow the DC-DC converter as follows, because the
DC-DC converter may fall from the substrate during reflowing.
Maximum Peak Temperature
Cooling Rate
235 ºC.
Less than 3 ºC. per second
DC-DC Converter
Substrate
www.murata-ps.com/support