OKL-T/3-W5 Series
www.murata-ps.com
Programmable Output 3-Amp iLGA SMT PoLs
PRODUCT OVERVIEW
The OKL-T/3-W5 series are miniature non-iso-
lated Point-of-Load (PoL) DC/DC power converters
for embedded applications. The tiny form factor is
configured on a Land Grid Array (LGA) assembly
measuring only 0.48 x 0.48 x 0.244 inches max.
(12.2 x 12.2 x 6.2 mm max.).
The wide input range is 2.4 to 5.5 Volts DC.
The maximum output current is 3 Amps. Based
on fixed-frequency synchronous buck converter
switching topology, the high power conversion
efficient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, over-
current and over temperature protections.
An optional sequence/tracking feature allows
power sequencing of PoL’s. These units meet all
standard UL/EN/IEC 60950-1 safety certifications
(2nd Edition) and RoHS-6 hazardous substance
compliance.
Typical unit
FEATURES
■ iLGA inspectable Land Grid Array
■ 2.4-5.5Vdc input voltage range
Contents
Page
■ Programmable output voltage from 0.6-3.63Vdc
■ Drives 200 μF ceramic capacitive loads
■ High power conversion efficiency at 95.3%
■ Outstanding thermal derating performance
■ Over temperature and over current protection
■ On/Off control
Description, Connection Diagram, Photograph
Ordering Guide, Model Numbering, Product Label
1
2
3
4
5
8
15
Mechanical Specifications, Input/Output Pinout
Detailed Electrical Specifications
Output Voltage Adjustment, Application Notes
Performance Data and Oscillograms
Tape and Reel Information
■ Meets UL/EN/IEC 60950-1 safety, 2nd Edition
■ RoHS-6 hazardous substance compliance
■ Sequence/Tracking operation (optional)
Connection Diagram
+Vin
+Vout
Sense
tꢀ4XJUDIJOH
tꢀ'JMUFST
F1
On/Off
Control
Controller
tꢀ$VSSFOUꢀ4FOTF
External
DC
Trim
Power
Source
Reference and
Error Amplifier
Open = On
Closed = Off
(Positive
On/Off)
Common
Common
Sequence/Tracking
(OKL2 Models)
Figure 1. OKL-T/3-W5
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifications.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
email: sales@murata-ps.com