OxiCap NOJ Series
Niobium Oxide Capacitor
• Non-burn safe technology
• Reliability level: 0.5%/1000 hrs.
• 6 case sizes available
• Environmentally friendly
• IBM global approval received in 2004
• Elektra Award received in 2005
• CV range: 4.7-1000μF / 1.8-10V
Elektra Award
2005
CASE DIMENSIONS: millimeters (inches)
EIA
EIA
Metric
L 0ꢀ20
(0ꢀ008)
W+0ꢀ20 (0ꢀ008) H+0ꢀ20 (0ꢀ008)
W1 0ꢀ20
(0ꢀ008)
A+0ꢀ30 (0ꢀ012)
Code
S Minꢀ
Code
–0ꢀ10 (0ꢀ004)
1.60 (0.063)
2.80 (0.110)
3.20 (0.126)
4.30 (0.169)
4.30 (0.169)
6.10 (0.240)
–0ꢀ10 (0ꢀ004)
1.60 (0.063)
1.90 (0.075)
2.60 (0.102)
2.90 (0.114)
4.10 (0.162)
3.55 (0.140)
–0ꢀ20 (0ꢀ008)
0.80 (0.031)
0.80 (0.031)
1.30 (0.051)
1.30 (0.051)
1.30 (0.051)
1.30 (0.051)
L
W
A
B
C
D
E
V
1206 3216-18
1210 3528-21
2312 6032-28
2917 7343-31
2917 7343-43
2924 7361-38
3.20 (0.126)
3.50 (0.138)
6.00 (0.236)
7.30 (0.287)
7.30 (0.287)
7.30 (0.287)
1.20 (0.047)
2.20 (0.087)
2.20 (0.087)
2.40 (0.094)
2.40 (0.094)
3.10 (0.120)
1.10 (0.043)
1.40 (0.055)
2.90 (0.114)
4.40 (0.173)
4.40 (0.173)
4.40 (0.173)
H
A
S
A
W1
For part marking see page 169
W1 dimension applies to the termination width for A dimensional area only.
HOW TO ORDER
NOJ
D
107
M
006
R
WJ
—
Type
Case Size
See table
above
Capacitance Code Tolerance Rated DC Voltage
Packaging
R = Pure Tin 7" Reel
S = Pure Tin 13" Reel
Specification
Suffix
WJ = Standard
Suffix
Additional
characters may be
added for special
requirements
1st two digits
represent significant
figures, 3rd digit
represents multiplier
in pF
M= 20%
001 = 1.8Vdc
002 = 2.5Vdc
004 = 4Vdc
006 = 6.3Vdc
010 = 10Vdc
V = Dry pack Option
(selected codes only)
with exception of
D, E, V cases
TECHNICAL SPECIFICATIONS
Technical Data:
All technical data relate to an ambient temperature of +25°C is not stated
Capacitance Range:
Capacitance Tolerance:
4.7 μF to 1000 μF
20%
Leakage Current DCL:
0.02CV
Rated Voltage DC (VR)
Category Voltage (VC)
Surge Voltage (VS)
Surge Voltage (VS)
Temperature Range:
Reliability:
ꢀ
+85°C:
1.8
1.2
2.3
1.6
2.5
1.7
3.3
2.2
4
6.3
4
8
10
7
13
8
ꢀ
+105°C:
2.7
5.2
3.4
ꢀ
+85°C:
ꢀ
+105°C:
5
-55°C to +105°C
0.5% per 1000 hours at 85°C,
Meets requirements of AEC-Q200
V
R, 0.1Ω/V series impedance, 60% confidence level
118 ■ JANUARY 2014