UTZ-SC0284_5
2012/10/02
]
Blue Laser Diode
NDB4116
ꢀ
Features
Outline Dimension
• Optical Output Power: CW 100mW
Unit (mm)
Φ
• Can Type: φ 5.6 mm Floating Mounted with Photo Diode and Zener Diode
Φ
ꢀ
Absolute Maximum Ratings
(90°)
Absolute
Maximum Ratings
Emitting Point
(0.4)
Item
Symbol
Unit
1.0±0.1
Optical Output Power
Allowable Reverse Current
PD Reverse Voltage
Po
Ir (LD)
Vr (PD)
Tstg
120
85
mW
mA
V
Z+
Φ
Φ
4.2±0.2
3.55±0.1
5
Storage Temperature
-40 ~ 85
-10 ~ 60
°C
Emitting Point
Reference Plane
Operating Case Temperature
Tc
°C
4×Φ 0.43±0.08
ꢀ
Initial Electrical/Optical Characteristics
(Tc=25°C)
Item
Condition Symbol Min Typ. Max Unit
3
Optical Output Power
CW
Po
λp
-
-
100
450
50
mW
nm
X+
1
2
Peak Wavelength
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Po=100mW
CW
440
10
445
25
4
Φ
2.0±0.2
Ith
Iop
mA
mA
W/A
Y+
Po=100mW
CW
80
100
1.3
5.3
8.5
140
1.8
( ) are reference figures
Pin Connection
0.8
4.5
7.0
η
Po=100mW
Po=100mW
Vop
6.0
V
°
Parallel
Beam
12.5
θ//
θ⊥
Divergence*
°
°
°
Perpendicular Po=100mW
Parallel Po=100mW
Perpendicular Po=100mW
Po=100mW
* Full angle at 50% from peak intensity
17.0 23.5 25.0
Beam
-2.5
-3.0
0.2
-
-
2.5
3.0
2.0
∆θ//
∆θ⊥
Im
Pointing
Accuracy
Monitor Current**
1.0
mA
This model has a Zener Diode built in
as a protection circuit against static
electricity.
** Monitor Current is short time power reference purpose only. Not guaranteed for
accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
ꢁ
Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
ꢁ
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
ꢂHEADQUARTERS
NICHIA CORPORATION
http://www.nichia.co.jp
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311 FAX: +81-884-21-0148
ꢂCONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-