5秒后页面跳转
MPT-200A PDF预览

MPT-200A

更新时间: 2024-09-19 03:48:35
品牌 Logo 应用领域
ASTRODYNE /
页数 文件大小 规格书
4页 441K
描述
200W 1~4 Output for Medical Type

MPT-200A 数据手册

 浏览型号MPT-200A的Datasheet PDF文件第2页浏览型号MPT-200A的Datasheet PDF文件第3页浏览型号MPT-200A的Datasheet PDF文件第4页 
mps/d/t/q-200 erieꢀ  
200W 1~4 Output for Medical Type  
Features  
Universal AC�input�/�Full�range  
Low�leakage�current�<180 A  
Protections:Short�circuit/Over�load/Over�voltage/Over�temperature  
Free�air�convection�for�140W�and�forced�air�convection�for�200W  
UL2601-1�medical�safety�approved  
With�power�good�and�fail�signal�output  
Built-in�remote�ON-OFF�control  
Built-in�remote�sense�function  
Fixed�switching�frequency�at�100KHz  
3�years�warranty  
Specification  
AC�INPUT�VOLTAGE  
90~264�VAC,�47~440Hz�/�127~370VDC.  
WORKING�TEMP.  
Whole�series�can�operate�from�-20~70 .�Please�refer  
to�the�derating�curves.  
POWER�FACTOR�(Typ.)  
PF>0.95/230VAC����������PF>0.98/115VAC�at�full�load  
WORKING�HUMIDITY  
20~90%�RH�non-condensing.  
AC�INPUT�CURRENT (Typ.)  
Maximum�input�current�3.5A at�115VAC,�60Hz�or  
1.6A at�230VAC,�60Hz�with�100%�output�load.  
STORAGE�TEMP.,�HUMIDITY  
-40~+85 ,�10~90%�RH  
INRUSH�CURRENT (Typ.)  
TEMP.�COEFFICIENT  
0.04%/ on�all�outputs�at�full�load�between�0~50 of�ambient�temperature.  
Inrush�current�is�less�than�25A at�115VAC�or  
less�than�40A at�230VAC�under�cold�start  
conditions.�Limiting�provided�by�internal  
thermistors.  
VIBRATION  
2G�of�acceleration,�vibrating�frequency�adjust�from�10Hz�~500Hz�within�a  
10-minute�cycle.�6�testing�cycles�(60�minutes)�each�along�X, Y,�Z�axes.  
SETUP,�RISE�TIME  
1000ms,�20ms�/�230VAC at�full�load  
3000ms,�20ms�/�115VAC�at�full�load  
SAFETY STANDARDS  
Medical : UL2601-1, TUV�EN60601-1�approved  
Commercial�: Also�design�refer�to�UL60950-1, TUV�EN60950-1  
HOLD-UP TIME (Typ.)  
16ms�/�230VAC�at�full�load  
16ms�/�115VAC�at�full�load  
WITHSTAND�VOLTAGE  
4000VAC�between�input�and�output  
1500VAC�between�input�and�F.G.  
500VAC�between�output�and�F.G.  
LEAKAGE�CURRENT  
Leakage�current�is�less�than�180 A at�264VAC�for  
earth�leakage�current  
Leakage�current�is�less�than�100 A at�264VAC�for  
patient�leakage�current  
ISOLATION�RESISTANCE  
>100M�Ohms�for�I/P-O/P,�I/P-FG,�O/P-FG�by�using�500VDC�test�voltage.  
EMI�COMPLIANCE  
EMI�Specifications  
Conducted�&�Radiation  
DC�OUTPUT ADJ.�RANGE  
Compliance�Level  
EN55011,�Class�B  
EN55022,�Class�B  
EN61000-3-2  
DC�output�voltage�(or�CH1�of�multiple�output�models)  
can�be�adjusted�between�-5%~+10%�rated�output  
voltage�by�potential�meter.  
Harmonic�distortion  
Voltage�flicker  
EN61000-3-3  
OVER�LOAD�PROTECTION  
Fully�protected�against�short�circuit�and�output�overload.  
The�hiccup�type�protection�will�be�activated�at�120~160%  
rated�load�and�recovers�automatically�after�fault�condition  
is�removed.  
EMS�COMPLIANCE  
EMS�Specification  
ESD�air  
ESD�contact  
RF�field�susceptibility  
Compliance�Level  
EN61000-4-2, Level�3,�8KV  
EN61000-4-2, Level�2,�4KV  
EN61000-4-3, Level�2,�3V/m  
Level�3,�10V/m  
EN61000-4-4, Level�2,�1KV/5KHz  
Level�3,�2KV/5KHz  
EN61000-4-5, Level�4,�2KV/Line-Line  
4KV/Line-Earth  
EN61000-4-6, Level�2,�3Vrms/m  
Level�3,�10Vrms/m  
EN61000-4-8, Level�2,�3A/m  
Level�3,�10A/m  
EN61000-4-11,Compliance  
ENV50204, Level�2,�3V/m,�900MHz  
Level�3,�10A/m,�900MHz  
OVER�VOLTAGE�PROTECTION  
Provided�on�output�channel�1�only�at�115%~135%  
rated�output�voltage.  
Output�will�be�shut�down�when�this�protection�is�activated.  
EFT(Electrical�Fast Transient)/Burst  
Lightning/Surge  
OVER�TEMPERATURE�PROTECTION  
Conducted�RF�susceptibility  
Magnetic�field�immunity  
When�the�temperature�of TSW1�which�detect on�heat�sink�of  
power�transistor�reaches�95 This�protection�is�activated.  
Then�output�will�be�shut�down�and�recovers�automatically  
after�temperature�goes�down.  
Voltage�dip,�interruption  
Digital�phone�carrier�immunity  
POWER�GOOD�/�FAIL SIGNAL  
TTL logic�high�for�power�good�and TTL low�for  
power�fail.�When�the�output�voltage�reaches�90%�of  
rated�value,�a�+5V TTL signal�will�be�sent�out�with�a  
10~500ms�delay; At�least�1ms�before�the�output  
voltage�goes�below�90%�of�the�rated�value,�the TTL  
signal�will�be�turned�off.  
MTBF  
262,100�hours�min.�at�full�load�and�25 of�ambient��temperature,  
calculated�per�MIL-HDBK-217F.  
DIMENSION�(L*W*H)  
177.8x107.95x35.5mm�or�7"x4.25"x1.4"  
*�MPS-200-3.3�does�not�have�this�function.  
PACKING  
0.66Kg;�24pcs/16.8Kg/1.04CUFT  
REMOTE�CONTROL  
RC+/RC-:0�~�0.8V=power�on;�4�~�10V=power�off�sink�current<4~10mA  
300 myleꢀ sꢁanꢂiꢀh Blvꢂ., taunꢁon, mA 02780  
ph: 1-800-823-8082 Fax: 508-823-8181  
WWW.AstROdYNE.COm  

与MPT-200A相关器件

型号 品牌 获取价格 描述 数据表
MPT-200B MPD

获取价格

Low Cost, 1-4 Output 200W EN60601 (Medical) Approved AC/DC Power Supplies
MPT-200B ASTRODYNE

获取价格

200W 1~4 Output for Medical Type
MPT-200B MEANWELL

获取价格

1~4 Output Medical Type
MPT-200C MEANWELL

获取价格

1~4 Output Medical Type
MPT-200C MPD

获取价格

Low Cost, 1-4 Output 200W EN60601 (Medical) Approved AC/DC Power Supplies
MPT-200C ASTRODYNE

获取价格

200W 1~4 Output for Medical Type
MPT-200D ASTRODYNE

获取价格

200W 1~4 Output for Medical Type
MPT-200D MPD

获取价格

Low Cost, 1-4 Output 200W EN60601 (Medical) Approved AC/DC Power Supplies
MPT-200D MEANWELL

获取价格

1~4 Output Medical Type
MPT2-106-01-L-T SAMTEC

获取价格

Board Connector, 18 Contact(s), 3 Row(s), Male, Straight, Solder Terminal,