MPB150 Dual-Output AC-DC Series Data Sheet
Features
• RoHS compliant for all six substances
• High power density in an industry-standard 3" x 5"
footprint
• Power Factor Correction (PFC) meets EN61000-3-2
• Main output remote sense
• Power Good signals
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
EN61000-4-2/-3/-4/-5
Description
The MPB150 Series incorporates patented high efficiency circuitry, high power density and active Power Factor
Correction (PFC) to meet the requirements of networking and data communications systems, as well as commercial
and industrial configurations.
MPB150’s deliver a regulated main output plus a second 12V output for fans or other system functions. The MPB150
is rated for convection as well as forced-air cooling. Full output power is available with as few as 15 Cubic Feet per
Minute (CFM) forced-air cooling.
The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.
Model Selection
OUTPUT
VOLTAGE
(VOLTS)
MAXIMUM OUTPUT
CURRENT (AMPS),
130 LFM
TOTAL
REGULATION
%
RIPPLE & NOISE
% pk-pk
MODEL
REGULATION RANGE
(NOTE 1)
MPB150-2012G
(NOTE 2, 3, 4)
+12V
12V
+24V
12V
+48V
12V
12.5A
0.5A
6.0A
0.5A
±.1A
0.5A
±±3
±53
±±3
±53
±±3
±53
13
13
13
13
13
13
11.64V to 12.±6V
11.40V to 12.60V
2±.28V to 24.72V
11.40V to 12.60V
46.56V to 49.44V
11.40V to 12.60V
MPB150-2024G
(NOTE 2, 3, 4)
MPB150-2048G
(NOTE 2, 3, 4)
NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) Maximum forced-air output power is 150 watts with 15 CFM airflow.
3) Maximum convection output power is 70 watts.
4) V2 is isolated from V1 and can be used as a negative or positive output.
APR 28, 2006 revised to JAN 24, 2007
Page 1 of 4
www.power-one.com