描述
DC INPUT LIMIT ALARM

MP1112-F-RH 数据手册

 浏览型号MP1112-F-RH的Datasheet PDF文件第2页浏览型号MP1112-F-RH的Datasheet PDF文件第3页浏览型号MP1112-F-RH的Datasheet PDF文件第4页 
Limit Alarms M-PAC  
MODEL  
DC INPUT LIMIT ALARM  
MP1000-1023  
MODEL & SUFFIX CODE SELECTION  
50  
(1.97)  
MP10/❑  
MODEL  
80  
(3.15)  
INPUT TYPE  
SET  
1
SPAN  
ZERO  
0 : DC current or voltage  
RELAY CONTACT OUTPUT  
M•PAC  
LIMIT ALARM  
SET  
1
DEADBAND  
SET  
2
DEADBAND  
0 : Single (Hi) trip, non-latching  
1 : Single (Hi) trip, latching  
132  
(5.20)  
SET  
2
2 : Dual (Hi/Lo) trip, non-latching  
SETPOINT CONTROL  
mm (inch)  
Functions & Features  
0 : Front-accessed three-turn screwdriver adjust.  
2 : Remote dial connections (total resistance 1k – 100k)  
3 : DC programmable (0 – 1V)  
INPUT RANGE  
• Accepting a large variety of DC inputs and pro-  
viding relay contact closure(s) at a preset input level  
• Single, latching or dual setpoint • Failsafe opera-  
tion available • Deadband adjustable from 1 to 100%  
• Indicator LED provided  
Current  
Voltage  
A : 4 – 20mA DC  
B : 2 – 10mA DC  
C : 1 – 5mA DC  
D : 0 – 20mA DC  
E : 0 – 16mA DC  
F : 0 – 10mA DC  
G : 0 – 1mA DC  
H : 10 – 50mA DC  
Z : Specify current  
1 : 0 – 10mV DC  
2 : 0 – 100mV DC  
3 : 0 – 1V DC  
4 : 0 – 10V DC  
5 : 0 – 5V DC  
6 : 1 – 5V DC  
U1 : Specify voltage  
(10span<100mV)  
U2 : Specify voltage  
(0.1span<1V)  
U3 : Specify voltage  
(1Vspan)  
Typical Applications  
• Annunciator • Various alarm applications  
GENERAL SPECIFICATIONS  
Construction: plug-in  
Connection: M3.5 screw terminals on base socket  
Housing material: flame-resistant resin (black)  
Isolation: input to output to power  
(non-isolated between I/O with Option V)  
Zero/span adjustments: ±5% (front)  
Setpoint adjustments: front accessed three-turn  
screwdriver, remote dial potentiometer  
or DC input  
Deadband adjustments: front accessed single-turn  
screwdriver; 1 – 100%  
Front LEDs: red lights turn on at a tripped condition  
Power ON timer: relays de-energized for approx. 2  
seconds after power is turned on.  
POWER INPUT  
F : 120V AC  
J : 240V AC  
R : 24V DC  
S : 12V DC  
OPTIONS  
H : Latching operation for dual trip (102X only);  
Reset at power off (5 seconds min.)  
R : Reversed relay sense  
T : Transmitter output (0 – 1V DC)  
V : Relay drive voltage output  
X : Lo-trip sense for single trip; Lo/Lo for dual trip  
Y : Hi/Hi-trip sense for dual trip (102X only)  
ORDERING INFORMATION  
Specify code number and variables.  
Code number (e.g. MP1000-6-F/T/V)  
Special input range (For codes Z, U1, U2 & U3)  
P. 1 / 4  
ES-9801 Rev.6  

与MP1112-F-RH相关器件

型号 品牌 获取价格 描述 数据表
MP1112-F-RR MSYSTEM

获取价格

DC INPUT LIMIT ALARM
MP1112-F-RT MSYSTEM

获取价格

DC INPUT LIMIT ALARM
MP1112-F-RV MSYSTEM

获取价格

DC INPUT LIMIT ALARM
MP1112-F-RX MSYSTEM

获取价格

DC INPUT LIMIT ALARM
MP1112-F-RY MSYSTEM

获取价格

DC INPUT LIMIT ALARM
MP1112-F-SH MSYSTEM

获取价格

DC INPUT LIMIT ALARM
MP1112-F-SR MSYSTEM

获取价格

DC INPUT LIMIT ALARM
MP1112-F-ST MSYSTEM

获取价格

DC INPUT LIMIT ALARM
MP1112-F-SV MSYSTEM

获取价格

DC INPUT LIMIT ALARM
MP1112-F-SX MSYSTEM

获取价格

DC INPUT LIMIT ALARM