Model Selection Guide
Input
Output
Output
Capacitive
Load
Fuse Rating
Slow-Blow
(mA)
Model
Number
Efficiency
(%, Typ)
Voltage (VDC)
Current (mA)
Voltage Current
Current
(µF Max)
(VDC)
(mA, Max) (mA, Min)
Nominal
12
Range
Full-Load No-Load
MG812S-03RW
MG812S-05RW
MG812S-12RW
MG812S-15RW
MG812S-24RW
MG812D-12RW
MG812D-15RW
MG824S-03RW
MG824S-05RW
MG824S-12RW
MG824S-15RW
MG824S-24RW
MG824D-12RW
MG824D-15RW
MG848S-03RW
MG848S-05RW
MG848S-12RW
MG848S-15RW
MG848S-24RW
MG848D-12RW
MG848D-15RW
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
564
823
792
796
788
788
789
282
407
391
393
390
394
385
141
206
196
197
195
195
193
10
10
10
10
10
10
10
10
10
10
10
10
10
10
8
3.3
5.0
1,600
1,600
665
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
680
680
330
330
150
150
150
680
680
330
330
150
150
150
680
680
330
330
150
150
150
78
81
84
84
85
85
84
78
82
85
85
86
85
86
78
81
85
85
86
86
86
1,600
1,600
1,600
1,600
1,600
1,600
1,600
800
12
12
12.0
15.0
24.0
12.0
15.0
3.3
12
535
12
335
12
335
12
265
24
1,600
1,600
665
24
5.0
800
24
12.0
15.0
24.0
12.0
15.0
3.3
800
24
535
800
24
335
800
24
335
800
24
265
800
48
1,600
1,600
665
400
48
8
5.0
400
48
8
12.0
15.0
24.0
12.0
15.0
400
48
8
535
400
48
8
335
400
48
8
335
400
48
8
265
400
Notes:
Typical Connection
1. The specified maximum capacitive load is for each output.
2. When measuring output ripple,it is recommended that an external 0.47 µF ceramic capacitor
be placed in parallel from the +VOUT pin to the -VOUT pin for single output models,or from each
output to common for dual output models.
EMI Characteristics
Parameter
Standard
Criteria
Level
Class A
Class A
8 kV Air
6 kV Contact
10V/m
2 kV
1 kV
10 Vrms
3A/m
Radiated Emissions
EN 55014, EN 55024
EN 55022
3. Transient recovery is measured to within a 1% error band for a load step change of
25%.
Conducted Emissions
4. Output overload protection is provided by a Hiccup circuit with auto-recovery.
ESD
EN 61000-4-2
A
5. Output short circuit protection is provided by a Hiccup circuit with auto-recovery.
6. These converters are specified for operation without external components.However,in some
applicationstheadditionofinput/outputcapacitors,asshowninthetypicalconnectiondiagram
at right,will enhance stability and reduce output ripple.This simple connection includes a low
ESR (<1Ω at 100 kHz) capacitor connected across the input. It is recommended that
a 3.3 µF be used for 12V input models and a 2.2 µF be used for 24V & 48V input
units. To improve the output ripple performance, a 3.3 µF is connected across the
output. For dual output units, a 3.3 µF capacitor should be connected from each output to
common. For applications where the circuit must meet or exceed EN 61000-4-4 (5), refer to
the note under the typical connection diagram.
RS
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
A
A
A
A
A
EFT, See Note 6
Surge, See Note 6
CS
PFMF
Typical Connection
7. Operationatnoloadwillnotdamagetheseunits,however,theymaynotmeetallspecifications.
8. It is recommended that a fuse be used on the input of a power supply for protection. See
the Model Selection table above for the correct rating.
Derating Curve
Notes:
To meet the specified EN 61000-4-4 and EN 61000-4-5 limits, an external capaci-
tor must be connected across the input pins of the module (C1). A 220 µF/100V
capacitor is recommended. This capacitor should be mounted as close to the module as
possible.
MicroPower Direct