The slotted lead option is currently
available but not, recommended for
new designs.
Features
■ Axial/radial leaded
■ Fully compatible with current industry
standards
■ Weldable nickel terminals
■ Very low internal resistance
■ RoHS compliant*
LS
190
0144T
■ Agency recognition:
MF-LS Series - PTC Resettable Fuses
Electrical Characteristics
1 Hour (R )
1
Tripped
Power
Initial
Max. Time
to Trip
Post-Trip
I
I
trip
hold
Resistance
Resistance
Dissipation
V max.
I max.
Amps
Model
Volts
Amperes
Ohms
Ohms
Amperes Seconds
Watts
at 23 °C
at 23 °C
at 23 °C
at 23 °C at 23 °C
at 23 °C
Hoꢂd
Trip
2.5
3.8
3.8
3.8
4.2
4.2
5.2
6.3
6.8
Min.
Max.
0.130
0.068
0.068
0.068
0.057
0.057
0.042
0.031
0.027
Max.
0.260
0.120
0.120
0.120
0.100
0.100
0.076
0.055
0.050
Tꢁp.
1.5
2.0
2.0
2.0
1.9
1.9
2.3
2.0
2.7
MF-LS100S
MF-LS180
MF-LS180L
MF-LS180S
MF-LS190
MF-LS190RU
MF-LS260
MF-LS300
MF-LS340
24
24
24
24
24
15
24
24
24
100
100
100
100
100
100
100
100
100
1.0
1.8
1.8
1.8
1.9
1.9
2.6
3.0
3.4
0.070
0.040
0.040
0.040
0.030
0.030
0.025
0.015
0.016
5
9
7.0
2.9
2.9
2.9
3.0
3.0
5.0
4.0
5.0
9
9
10
10
13
15
17
NOTE: Sꢂotted option avaiꢂabꢂe on aꢂꢂ modeꢂs.
Environmental Characteristics
Operating/Storage Temperature........................... -40 °C to +85 °C
Maximum Device Surface Temperature
in Tripped State ................................................ 125 °C
Passive Aging....................................................... +85 °C, 1000 hours............................................... 10 ꢀ tꢁpicaꢂ resistance change
Humiditꢁ Aging...................................................... +85 °C, 85ꢀ R.H. 7 daꢁs...................................... 5 ꢀ tꢁpicaꢂ resistance change
Vibration ............................................................... MIL-STD-883C,..................................................... No change
Condition A
Test Procedures And Requirements For Model MF-LS Series
Test
Test Conditions
Accept/Reject Criteria
Visuaꢂ/Mech..................................................... Verifꢁ dimensions and materiaꢂs.......................Per MF phꢁsicaꢂ description
Resistance....................................................... In stiꢂꢂ air @ 23 °C.............................................Rmin ≤ R ≤ R1max
Time to Trip...................................................... At specified current, Vmax, 23 °C.....................T ≤ max. time to trip (seconds)
Hoꢂd Current.................................................... 30 min. at Ihoꢂd .................................................No trip
Trip Cꢁcꢂe Life.................................................. Vmax, Imax, 100 cꢁcꢂes....................................No arcing or burning
Trip Endurance................................................ Vmax, 48 hours.................................................No arcing or burning
UL Fiꢂe Number ............................................... E 174545S
CSA Fiꢂe Number............................................. CA 110338
TÜV Fiꢂe Number............................................. R2057213
Thermal Derating Chart - I
I
(Amps)
hold/ trip
Ambient Operating Temperature
23 ºC 40 ºC 50 ºC
Model
-40 ºC
-20 ºC
0 ºC
60 ºC
70 ºC
85 ºC
MF-LS100S
MF-LS180
MF-LS180L
MF-LS180S
MF-LS190
MF-LS190RU
MF-LS260
MF-LS300
MF-LS340
1.80 / 4.50 1.60 / 4.00
3.10 / 6.54 2.60 / 5.49
3.10 / 6.54 2.60 / 5.49
3.10 / 6.54 2.60 / 5.49
3.30 / 7.29 2.80 / 6.19
3.30 / 7.29 2.80 / 6.19
4.30 / 8.60 3.70 / 7.40
5.10 / 10.7 4.40 / 9.24
5.50 / 11.0 4.70 / 9.40
1.40 / 3.50 1.00 / 2.50 0.80 / 2.00 0.70 / 1.75 0.60 / 1.50 0.40 / 1.00 0.20 / 0.50
2.20 / 4.64 1.80 / 3.80 1.30 / 2.74 1.10 / 2.32 0.90 / 1.90 0.60 / 1.27 0.20 / 0.42
2.20 / 4.64 1.80 / 3.80 1.30 / 2.74 1.10 / 2.32 0.90 / 1.90 0.60 / 1.27 0.20 / 0.42
2.20 / 4.64 1.80 / 3.80 1.30 / 2.74 1.10 / 2.32 0.90 / 1.90 0.60 / 1.27 0.20 / 0.42
2.40 / 5.31 1.90 / 4.20 1.40 / 3.09 1.20 / 2.65 1.10 / 2.43 0.70 / 1.55 0.40 / 0.88
2.40 / 5.31 1.90 / 4.20 1.40 / 3.09 1.20 / 2.65 1.10 / 2.43 0.70 / 1.55 0.40 / 0.88
3.10 / 6.20 2.60 / 5.20 1.90 / 3.80 1.60 / 3.20 1.40 / 2.80 1.10 / 2.20 0.60 / 1.20
3.70 / 7.77 3.00 / 6.30 2.30 / 4.83 1.90 / 3.99 1.60 / 3.36 1.20 / 2.52 0.60 / 1.26
4.00 / 8.00 3.40 / 6.80 2.60 / 5.20 2.20 / 4.40 1.90 / 3.80 1.50 / 3.00 0.80 / 1.60
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.