MDA3KP6.0A to MDA3KP40A
High-Reliability
screening available in
reference to
Surface Mount 3000 W Vertical Transient
Available
Voltage Suppressor Array
MIL-PRF-19500
DESCRIPTION
The MDA series of 3000 W Transient Voltage Suppressors (TVSs) protects a variety of
voltage-sensitive components from destruction or degradation. They can protect from
secondary lightning effects per IEC61000-4-5 and class levels defined herein, or for inductive
switching environments and induced RF protection. Since their response time is virtually
instantaneous, they can also be used in protection from ESD and EFT per IEC61000-4-2 and
IEC61000-4-4
Important: For the latest information, visit our website http://www.microsemi.com.
FEATURES
MDA3KPxxA
•
•
•
Available in both unidirectional and bidirectional construction
Selections for 6.0 to 40 volts standoff voltages (VWM
)
Optional upscreening is available with various screening and conformance inspection options
based on MIL-PRF-19500. Refer Micronote 129 for more details on the screening options.
MSC – Lawrence
6 Lake Street,
Lawrence, MA 01841
Tel: 1-800-446-1158 or
(978) 620-2600
•
•
•
High reliability with wafer fabrication and assembly lot traceability
All parts surge tested
Suppresses transients up to 3,000 W @ 10/1000 μs (see Figure 1)
Fax: (978) 689-0803
•
•
Moisture classification is Level 1 with no dry pack required per IPC/JEDEC J-STD-020B
3σ lot norm screening performed on standby current (ID)
APPLICATIONS / BENEFITS
MSC – Ireland
•
•
•
•
•
•
•
•
•
•
•
•
Suppresses transients up to 3000 watts @ 10/1000 µs
Protection from switching transients and induced RF
Protection from ESD, and EFT per IEC 61000-4-2 and IEC 61000-4-4
Secondary lightning protection per IEC61000-4-5 with 42 Ohms source impedance:
Class 1 – 4: MDA3KP6.0A to MDA3KP40A
Gort Road Business Park,
Ennis, Co. Clare, Ireland
Tel: +353 (0) 65 6840044
Fax: +353 (0) 65 6822298
Website:
www.microsemi.com
Secondary lightning protection per IEC61000-4-5 with 12 Ohms source impedance:
Class 1 – 3: MDA3KP6.0A to MDA3KP40A
Class 4: : MDA3KP6.0CA to MDA3KP18A
Secondary lightning protection per IEC61000-4-5 with 2 Ohms source impedance:
Class 2: MDA3KP6.0A to MDA3KP40A
Class 3: MDA3KP6.0A to MDA3KP18A
Class 4: MDA3KP6.0A to MDA3KP9.0A
*See Figure 3 for further temperature derating selection.
RF01243, Rev B
©2019 Microsemi Corporation
Page 1 of 7