MCS 0402, MCT 0603, MCU 0805, MCA 1206 - Professional
www.vishay.com
Vishay Beyschlag
TESTS AND REQUIREMENTS
All tests are carried out in accordance with the following
specifications:
Unless otherwise specified the following values apply:
Temperature: 15 °C to 35 °C
EN 60115-1, generic specification (includes tests)
Relative humidity: 45 % to 75 %
EN 140400, sectional specification (includes schedule for
qualification approval)
Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).
The components are mounted for testing on boards in
accordance with EN 60115-1, 4.31 unless otherwise
specified.
EN 140401-801, detail specification (includes schedule for
conformance inspection)
The components are approved in accordance with the
European CECC-system, where applicable. The following
table contains only the most important tests. For the full test
schedule refer to the documents listed above. The testing
also covers most of the requirements specified by
EIA/IS-703 and JIS-C-5202.
The requirements stated in the Test Procedures and
Requirements table are based on the required tests and
permitted limits of EN 140401-801. However, some
additional tests and a number of improvements against
those minimum requirements have been included.
The tests are carried out in accordance with IEC 60068 and
under standard atmospheric conditions in accordance with
IEC 60068-1, 5.3. Climatic category LCT/UCT/56 (rated
temperature range: Lower category temperature, upper
category temperature; damp heat, long term, 56 days) is
valid.
TEST PROCEDURES AND REQUIREMENTS
IEC
REQUIREMENTS
EN
60115-1
CLAUSE
60068-2
PERMISSIBLE CHANGE (R)
TEST
PROCEDURE
TEST
METHOD
STABILITY CLASS 0.5
STABILITY CLASS 1
Stability for product types:
MCS 0402
10 to 33.2 k
10 to 100 k
10 to 221 k
10 to 332 k
> 33.2 kto 4.99 M
1 to < 10 ;
> 100 k to 10 M
MCT 0603
MCU 0805
1 to < 10 ;
> 221 k to 10 M
1 to < 10 ;
> 332 k to 2 M
MCA 1206
4.5
-
-
Resistance
-
1 % R; 0.5 % R
Temperature
coefficient
At (20/- 55/20) °C and
(20/125/20) °C
4.8.4.2
50 ppm/K; 25 ppm/K
U = P70 x R or U = Umax.
whichever is the less
severe;
;
;
Endurance
at 70 °C:
Standard
1.5 h on; 0.5 h off;
operation mode
70 °C; 1000 h
70 °C; 8000 h
(0.25 % R + 0.05 )
(0.5 % R + 0.05 )
4.25.1
-
U = P70 x R or U = Umax.
whichever is the less
severe;
Endurance
at 70 °C:
Power
1.5 h on; 0.5 h off;
operation mode
70 °C; 1000 h
70 °C; 8000 h
125 °C; 1000 h
(0.5 % R + 0.05 )
(1 % R + 0.05 )
Endurance at
upper category
temperature
(0.25 % R + 0.05 )
(0.5 % R + 0.05 )
(1 % R + 0.05 )
4.25.3
4.24
-
155 °C; 1000 h
(0.5 % R + 0.05 )
(0.5 % R + 0.05 )
Damp heat,
steady state
(40 2) °C; 56 days;
(93 3) % RH
78 (Cab)
(1 % R + 0.05 )
Revision: 24-Jan-13
Document Number: 28705
8
For technical questions, contact: thinfilmchip@vishay.com