MAP55 SERIES
Power-One's MAP55 series of power supplies provides reliable, tightly
Other mechanical design innovations include metric and SAE
mounting inserts on each mounting surface to provide integration
flexibility. Dual-mode connectors provide traditional terminal block
connections or popular single row Molex connector mating.
regulated DC power for commercial and industrial systems. Wide-
range AC input and full international safety, EMI, and ESD
compliance ensure world-wide acceptance. All units bear the CE
Mark.
Single output models feature wide-range output adjustability to meet a
wide variety of standard and user specific output voltage requirements.
The MAP55 utilizes a thermally efficient U-channel chassis design,
which allows full power operation in convection cooled applications.
FEATURES
•
•
•
Wide Range Input for 110/220 VAC Applications
Meets EN55022, Conducted Class B Limits
Compact Footprint: 6.00" x 3.27" x 1.60"
(152.4mm x 83.1mm x 40.6mm)
•
•
Greater than 225,000 Hours MTBF
Metric and SAE Mounting Inserts
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 3)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
MAP40-1005
MAP55-1012 12V/15V
MAP55-1024 24V/28V
5V
4.7V to 5.50V
11.4V to 15.75V
23.5V to 28.5V
8A
11A
0.2%
0.2%
0.2%
1.5%
1%
1%
1%
1%
1%
5.0V to 5.2V
12.0V to 12.2V
23.8V to 24.2V
5.0/4.0A (Note 2)
2.5/2.2A (Note 2)
5.8/4.7A (Note 2)
2.9/2.5A (Note 2)
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
MULTIPLE OUTPUT MODEL SELECTION CHART – 55W CONTINUOUS OUTPUT POWER
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
PEAK OUTPUT
LINE
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
CURRENT
CURRENT (NOTE 1)
REGULATION
+5V
+12V
-5V
-12V
+5V
+24V
-12V
+12V
+5V
+12V
-12V
+12V
+5V
+15V
-5V
-15V
+5V
+24V
-15V
+15V
4.7V to 5.6V
Fixed
Fixed
Fixed
4.7V to 5.6V
Fixed
Fixed
Fixed
4.7V to 5.6V
Fixed
Fixed
Fixed
4.7V to 5.6V
Fixed
6A
3A
0.5A
0.5A
6A
1.5A
0.5A
0.5A
6A
8A
5A
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.0V to 5.2V
11.6V to 12.4V
-4.8V to -5.2V
-11.6V to -12.4V
5.0V to 5.2V
23.0V to 24.9V
-11.6V to -12.4V
11.6V to 12.4V
5.0V to 5.2V
11.6V to 12.4V
-11.6V to -12.4V
11.6V to 12.4V
5.0V to 5.2V
14.6V to 15.4V
-4.8V to -5.2V
-14.4V to -15.6V
5.0V to 5.2V
MAP55-4000
1A (Note 3)
1A (Note 3)
8A
2.5A
MAP55-4001
MAP55-4002
MAP55-4003
MAP55-4004
1A (Note 3)
1A (Note 3)
8A
3A
5A
0.5A
0.5A
6A
2.5A
0.5A
0.5A
6A
1.5A
0.5A
0.5A
1A (Note 3)
1A (Note 3)
8A
3.5A
Fixed
Fixed
4.7V to 5.6V
Fixed
1A (Note 3)
1A (Note 3)
8A
2.5A
1A (Note 3)
1A (Note 3)
23.0V to 24.9V
-14.5V to -15.5V
14.5V to 15.5V
Fixed
Fixed
NOTES: 1) Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded.
REV. 09/01