Data Sheet  
November 2001  
L9217A/G Low-Cost Line Interface  
with Reverse Battery and PPM  
Features  
Description  
Basic forward/reverse battery SLIC functionality at  
This general-purpose electronic subscriber loop  
a low cost  
interface circuit (SLIC) is optimized for low cost, while  
still providing a satisfactory set of features. This part  
is a pin-for-pin replacement for the Agere L9218/  
L9219 SLIC.  
Pin compatible with Agere Systems Inc. L9218/  
L9219 SLIC  
Low active power (typical 154 mW during on-hook  
transmission)  
The L9217 requires a 5 V power supply and single  
battery to operate. This device offers forward and  
reverse battery operation. The rate of battery rever-  
sal may be ramped to meet international require-  
ments. Additionally, a low-power scan mode, wherein  
all circuitry except the off-hook supervision is shut  
down to conserve power, is available.  
Low-power scan mode for low-power, on-hook  
power dissipation (57 mW typical)  
Distortion-free, on-hook transmission  
Convenient operating states:  
— Forward powerup  
— Reverse powerup  
— Low-power scan  
— Disconnect (high impedance)  
— PPM operational states  
The dc current limit may be programmed via a single  
external resistor. Both the loop supervision and ring  
trip supervision functions are offered with user-  
controlled thresholds via external resistors. Over-  
head is adequate for 3.14 dBm into 900 of on-hook  
transmission.  
Minimal external components required  
Two gain options to optimize the codec interface  
The device is periodic pulse metering (PPM) compat-  
ible, offering a convenient point for meter pulse injec-  
tion and filter point for rejection of the meter pulse  
signal. In the PPM active modes, overhead voltage is  
automatically increased to accommodate on-hook  
transmission of meter pulse signals. The level that  
the overhead is increased to is set by a single exter-  
nal resistor. In this way, the L9217 can accommodate  
high-voltage meter pulse signals.  
Adjustable supervision functions:  
— Off-hook detector with hysteresis  
— Ring trip detector  
Adjustable loop current limit  
Adjustable overhead voltage  
Ramped rate of battery reversal  
Periodic pulse metering (PPM) compatible  
The L9217 is offered with a receive gain that is opti-  
mized to interface to a first-generation type codec  
(L9217A). It is also offered with a gain option that is  
optimized to interface to a third- or fourth-generation  
type codec (L9217G). In both cases, minimizing  
external components is required at this interface.  
Thermal protection with thermal shutdown indica-  
tion  
Data control is via a parallel data control scheme.  
The device is available in a 28-pin PLCC package. It  
is built by using a 90 V complementary bipolar  
(CBIC) process.  

与LUCL9217GAR-D相关器件

型号 品牌 获取价格 描述 数据表
LUCL9217GAR-DT AGERE

获取价格

Low-Cost Line Interface with Reverse Battery and PPM
LUCL9218AAR-D AGERE

获取价格

Low-Cost Line Interface
LUCL9218AAR-DT AGERE

获取价格

Low-Cost Line Interface
LUCL9218GAR-D AGERE

获取价格

Low-Cost Line Interface
LUCL9218GAR-DT AGERE

获取价格

Low-Cost Line Interface
LUCL9219AAR-D AGERE

获取价格

Low-Cost Line Interface with Reverse Battery and Dual Current Limit
LUCL9219AAR-DT AGERE

获取价格

Low-Cost Line Interface with Reverse Battery and Dual Current Limit
LUCL9219GAR-D AGERE

获取价格

Low-Cost Line Interface with Reverse Battery and Dual Current Limit
LUCL9219GAR-DT AGERE

获取价格

Low-Cost Line Interface with Reverse Battery and Dual Current Limit
LUCL9310AP-D AGERE

获取价格

Line Interface and Line Access Circuit Full-Feature SLIC,Ringing Relay,and Test Access Dev