LTM8048
ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C, RUN = 12V (Note 3).
PARAMETER
CONDITIONS
BIAS = V
MIN
TYP
MAX
UNITS
l
l
Minimum Input DC Voltage
3.1
V
IN
V
DC Voltage
R
ADJ1
R
ADJ1
R
ADJ1
= 12.4k
= 6.98k
= 3.16k
2.5
5
12
V
V
V
OUT1
4.75
5.25
1
V
IN
Quiescent Current
V
= 0V
µA
µA
RUN
Not Switching
850
1.7
1.5
20
V
OUT1
V
OUT1
V
OUT1
Line Regulation
Load Regulation
Ripple (RMS)
6V ≤ V ≤ 31V, I = 0.15A
OUT
%
%
IN
0.05A ≤ I
≤ 0.2A
OUT
I
= 0.1A
mV
mA
V
OUT
Input Short Circuit Current
RUN Pin Input Threshold
RUN Pin Current
V
Shorted
30
OUT1
RUN Pin Rising
1.18
1.24
1.30
V
RUN
V
RUN
= 1V
= 1.3V
2.5
0.1
µA
µA
SS Threshold
0.7
–10
8
V
µA
mA
V
SS Sourcing Current
BIAS Current
SS = 0V
V
= 12V, BIAS = 5V, I
= 100mA
LOAD1
IN
Minimum BIAS Voltage (Note 4)
I
= 100mA
3.1
2.3
LOAD1
LDO (V
) Minimum Input DC Voltage
OUT2
(Note 5)
1.8
V
V
OUT2
Voltage Range
V
OUT1
V
OUT1
= 16V, R
= 16V, R
Open, No Load (Note 5)
= 41.2k, No Load (Note 5)
1.22
15.8
V
V
ADJ2
ADJ2
ADJ2 Pin Voltage
V
OUT1
V
OUT1
V
OUT1
= 2V, I
= 2V, I
= 2V, I
= 1mA (Note 5)
= 1mA, E- and I-Grades (Note 5)
= 1mA, MP-Grade (Note 5)
1.22
V
V
V
OUT2
OUT2
OUT2
l
l
1.19
1.15
1.25
1.29
V
V
Line Regulation
Load Regulation
2V < V
< 16V, I = 1mA (Note 5)
OUT2
1
2
5
mV
mV
OUT2
OUT2
OUT1
V
OUT1
= 5V, 10mA < I
= 300mA (Note 5)
OUT2
10
LDO Dropout Voltage
I
I
I
= 10mA (Note 5)
= 100mA (Note 5)
= 300mA (Note 5)
0.25
0.34
0.43
V
V
V
OUT2
OUT2
OUT2
V
Ripple (RMS)
C
BYP
= 0.01µF, I
= 300mA, BW = 100Hz to 100kHz (Note 5)
20
µV
RMS
OUT2
OUT2
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
range. The LTM8048MP is guaranteed to meet specifications over the
full –55°C to 125°C internal operating temperature range. Note that
the maximum internal temperature is determined by specific operating
conditions in conjunction with board layout, the rated package thermal
resistance and other environmental factors.
Note 2: The LTM8048 isolation is tested at 725VDC for one second in each
polarity.
Note 4: This is the BIAS pin voltage at which the internal circuitry is
powered through the BIAS pin and not the integrated regulator. See BIAS
Pin Considerations for details.
Note 3: The LTM8048E is guaranteed to meet performance specifications
from 0°C to 125°C. Specifications over the –40°C to 125°C internal
temperature range are assured by design, characterization and correlation
with statistical process controls. LTM8048I is guaranteed to meet
specifications over the full –40°C to 125°C internal operating temperature
Note 5: V
powered by applying a voltage to V
= 0V (Flyback not running), but the V
post regulator is
RUN
OUT2
.
OUT1
8048fg
3
For more information www.linear.com/LTM8048