Blocks and Holders  
Fuse Blocks  
General Information  
4. Determine if NEC, CSA, UL, or other requirements  
are applicable  
If fuse blocks will be installed in equipment to be submitted for agency  
approval, the requirements should be obtained from the approving  
agency in advance of fuse and fuse block selection.  
5. Select the type of wire termination  
A choice of three types of wire termination is available:  
a) Screw — for use with spade lugs or ring terminals.  
*
b) Screw with Pressure Plate — for use with solid or stranded wire  
*
without terminal. Recommended where vibration will be a factor.  
c) Box Lug — the most durable. For use with all types of solid wire and  
Class B and Class C stranded wire. Not for use with welding cable or  
other rope-stranded conductors.  
1/4” Quick Connect terminals rated for up to 20A are  
*
available on the Midget and Class CC fuse blocks.  
Fuse Block Selection  
The following guidelines should help simplify the selection of proper  
fuse blocks:  
Screw  
with  
Pressure  
Plate  
Screw  
(S)  
Box  
Lug  
(C)  
1. Determine the system voltage  
Since fuses are selected on the basis of system voltage, fuse blocks are  
(P)  
selected to match the voltage rating of the fuse.  
6. Decide on the number of poles in each block  
The number of poles for each set of fuses is determined by the  
characteristics of the circuit. The option to gang individual fuse blocks  
into long strips will be determined by the available space and by the  
type of wire being used.  
2. Determine the design short-circuit current  
Available and/or design short-circuit current is an important  
consideration when determining the class of fuse and fuse blocks to  
use. If available short-circuit current cannot be determined, or if it will  
vary with equipment location, select fuses with a 200,000 ampere  
interrupting rating (A.I.R.) and mating fuse blocks with a withstand rating  
of 200,000 amperes for maximum safety.  
7. Determine if fuse clips need to be reinforced  
Fuse clips may have a tendency to lose some of their tension over a  
period of time. This may be prevented by specifying reinforced fuse  
clips. Reinforced clips are standard on certain fuse blocks (see individual  
product pages).  
Class H fuse blocks will accept Class H or K5 fuses (which have an  
interrupting rating of up to 50,000 amperes) and Class R fuses (which  
have a 200,000 A.I.R.). To prevent the possibility of inserting a fuse  
with the incorrect interrupting rating, the use of Class R fuse blocks is  
recommended for use with Class R fuses. Use Class H fuse blocks with  
Class H or K5 fuses. These fuse blocks are dimensionally the same, but  
the Class R fuse blocks incorporate a rejection feature which allows only  
Class R fuses to be inserted.  
Ordering Information  
The Littelfuse fuse block part number consists of 6 or 7 components, as  
shown below and in the individual fuse block data tables.  
3. Determine the type and ampere rating of the fuse to be used  
In addition to voltage and interrupting rating as discussed above, the  
fuse ampere rating, opening characteristics (fast acting or time-delay)  
and size are other important considerations in fuse selection. Once the  
fuse type is selected, the mating fuse block can be chosen. Fuse blocks  
are available in 30, 60, 100, 200, 400 and 600 amp ratings, and may be  
used with a fuse rated at the corresponding amperage rating or below.  
For example, a fuse block rated at 30 amperes may be used with a fuse  
rated from 0 to 30 amperes.  
For all Class R, H, J, T and 15, 20  
& 60A Class G Fuse Blocks  
For all Class CC, Midget and 30A  
Class G Fuse Blocks  
© 2005 Littelfuse POWR-GARDProducts Catalog  
w w w . l i t t e l f u s e . c o m  
111  

与LR254003CR相关器件

型号 品牌 获取价格 描述 数据表
LR25400B BEL

获取价格

AC-DC Power Factor Correction Module,
LR25400B1 BEL

获取价格

AC-DC Power Factor Correction Module,
LR2540-5B BEL

获取价格

AC-DC Power Factor Correction Module,
LR2540-5F0 BEL

获取价格

AC-DC Power Factor Correction Module,
LR2540-6B BEL

获取价格

AC-DC Power Factor Correction Module,
LR2540-6F0 BEL

获取价格

AC-DC Power Factor Correction Module,
LR256 LRC

获取价格

Fast 1.2MHz Switching Frequency Requires Only 0.22uF Output Capacitor
LR25600-1 LITTELFUSE

获取价格

Class H/K5 and R Fuse Blocks
LR256001C LITTELFUSE

获取价格

FUSE HLDR CART 250V 600A CHASSIS
LR25600-3 LITTELFUSE

获取价格

Class H/K5 and R Fuse Blocks