Spec No.: JELF243B_0076D-01
P3/9
8. Mechanical Performance
No.
Item
Specification
Test method
8.1 Shear test
No significant mechanical damage or no Force application direction:
sign of electrode peeling off shall be
observed.
Applying force: 10 N
Holding time: 5 s±1 s
8.2 Bending test
No significant mechanical damage or no Test substrate: glass-epoxy substrate (100 mm × 40 mm ×
sign of electrode peeling off shall be
observed.
1.0 mm)
Pressurizing speed: 0.5 mm/s
Deflection: 2 mm
Holding time: 30 s
Pressure jig
R230
F
Deflection
Product
45
45
(in mm)
8.3 Vibration
Appearance shall have no significant
mechanical damage.
Oscillation frequency: 10 Hz to 2000 Hz to 10 Hz, for approx.
20 min
Total amplitude: total amplitude of 3.0 mm or acceleration
amplitude of 245 m/s2, whichever is smaller
Test time: 3 directions perpendicular to each other, 4 h for
each direction (12 h in total)
8.4 Drop
Appearance shall have no significant
mechanical damage.
The product shall be dropped so that it falls freely onto
concrete or a steel board.
Height: 1 m
Number of falls: 10 times
8.5 Solderability
90% or more of the outer electrode shall Flux: immersed in ethanol solution with a rosin content of
be covered with new solder seamlessly. 25(wt)% for 5 s to 10 s
Solder: Sn-3.0Ag-0.5Cu solder
Pre-heating: 150°C±10°C/60 s to 90 s
Solder temperature: 240°C±5°C
Immersion time: 3 s±1 s
8.6 Resistance to Appearance: No significant mechanical Flux: immersed in ethanol solution with a rosin content of
soldering heat damage shall be observed.
Inductance change rate: within ±30%
25(wt)% for 5 s to 10 s
Solder: Sn-3.0Ag-0.5Cu solder
Pre-heating: 150°C±10°C/60 s to 90 s
Solder temperature: 270°C±5°C
Immersion time: 10 s±1 s
Post-treatment: left at a room temperature for 24 h±2 h
9. Environmental Performance
The product is soldered on a substrate for test.
No.
Item
Specification
Test method
9.1 Heat
Appearance: No significant mechanical Temperature: 85°C±2°C
resistance
damage shall be observed.
Test time: 1000 h (+48 h, -0 h)
Inductance change rate: within ±30%
Post-treatment: left at a room temperature for 24 h±2 h
9.2 Cold
resistance
Appearance: No significant mechanical Temperature: -40°C±2°C
damage shall be observed.
Test time: 1000 h (+48 h, -0 h)
Inductance change rate: within ±30%
Post-treatment: left at a room temperature for 24 h±2 h
MURATA MFG CO., LTD