LPUB / LPZJL SERIES CERAMIC FILTER
FEATURES
• AM use
• RoHS Compliant (Note 7 exemption)
LPU 455B
LPZ 455JL
OPERATING CONDITIONS/ELECTRICAL CHARACTERISTICS
3dB
SELECTIVITY
SELECTIVITY
INSERTION
PART NUMBER
COMPOSITION
BANDWIDTH (KHz)
-9 KHZ OFF (dB) MIN. +9 KHZ OFF (dB) MIN. LOSS (dB) MAX.
LPU455B - (connected with IFT)
LPZ455JL - (connected with IFT)
10 ±±
5.5 ±1
5 (7.5)
18 (20)
± (5.5)
18 (20)
5 (±)
7 (±.5)
1 Element with IFT
2 Elements Direct Coupling Type
• Center frequency (fo) is available in a range of 450 to 470KHz. The standard tolerance of fo is ±±KHz. ꢀor synthesizers and digital indicators, ±ꢁKHz tolerance is also available.
• The LPZ455JL series, with its two directly coupled elements, has a high degree of selectivity. The series features excellent matching characteristics for IꢀT.
( ) = Typical values
PACKAGE DIMENSIONS (mm)
ITEM \ TYPE
LPU
B
LPZ
JL
7.5
3.5
WINDING SPECIFICATIONS
①—
①
①
—
①
①—
①
①—
①
①—
①
①—①
3
4
2
Bottom
view
70 T
115 T
7 T
68 T
84 T
14 T
1
6
UNLOADED Qu
TUNING CAPACITY
105
180pF
90
180pF
Figure 3) Recommended IFT Specifications
Connection
Input
1
2
3
3
2
1
Ground
Output
INPUT
OUTPUT
2.5 2.5
1
3
R1
LPU
Figure 1) LPU455B – Front and Side views
GROUND
2
RF
V.M.
Rg
R2
S.S.G.
7.0 ±0.3
7.0 ±0.3
Rg+R1=R2=input/output impedance
Figure 4) LPU Series – Measuring Circuit
3
2
1
1
2
3
6
: Input
: Ground
3
2
4
5
3.6
5
4
2.5 2.5
: Direct Coupled
: Output
LPZ
3K
Connection
1
2
3
Input
1
2
3
4
5
6
Ground
S.S.G.
Rg = 50Ω
RF
V.M.
3K
1
6
Direct Coupled
Direct Coupled
Ground
4
6
5
2.5 2.5
Output
Figure 2) LPZ455JL – Front, Side and Bottom views
Figure 5) LPZ Series – Measuring Circuit
ECS, INC. INTERNATIONAL 1105 S. RIDGEVIEW, OLATHE, KS 66062 • 913-782-7787 • 800-237-1041 • FAX 913-782-6991 • WWW.ECSXTAL.COM
CERAMIC FILTERS 82 CERAMIC FILTERS