60W Single Output Switching Power Supply
LPV-60 series
Features :
Constant voltage design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level (Note.8)
Fully isolated plastic case
Class
power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.7)
100% full load burn-in test
Low cost, high reliability
2 years warranty
IP67
LPS
( for 48V only)
( except for 5V,48V )
SPECIFICATION
MODEL
LPV-60-5
LPV-60-12
LPV-60-15
LPV-60-24
LPV-60-36
LPV-60-48
DC VOLTAGE
5V
12V
15V
24V
36V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
8A
5A
4A
2.5A
1.67A
1.25A
0 ~ 8A
40W
0 ~ 5A
60W
0 ~ 4A
60W
0 ~ 2.5A
60W
0 ~ 1.67A
60W
0 ~ 1.25A
60W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 8.0%
120mVp-p
5.0%
120mVp-p
150mVp-p
150mVp-p
150mVp-p
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
1.0%
6.0%
2.0%
Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms/230VAC
Note.4 90 ~ 264VAC
47 ~ 63Hz
16ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
LEAKAGE CURRENT
76%
83%
83%
86%
86%
86%
INPUT
1.2A/115VAC 1A/230VAC
COLD START 30A/115VAC
0.25mA / 240VAC
60A/230VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V
PROTECTION
ENVIRONMENT
41.4 ~ 48.6V
55.2 ~ 64.8V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48),
CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1
I/P-O/P:3KVAC
SAFETY STANDARDS
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
732Khrs min. MIL-HDBK-217F (25
162.5*42.5*32mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.4Kg; 32pcs/13.8Kg/0.56CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
File Name:LPV-60-SPEC 2012-03-20