Embedded Power for
Business-Critical Continuity
Rev. 7.8.09_4
LPS40 Series
ꢀ of 3
LPS40 Series
40 Watts
Total Power:
40ꢀ-ꢀ55ꢀWatts
Input Voltage: 85ꢀ-ꢀ264ꢀVAC
ꢀ
ꢀ
120ꢀ-ꢀ300ꢀVDC
Single
# of Outputs:
Electrical Specifications
Input
Special Features
•ꢀ Universalꢀinputꢀ
•ꢀ 3”ꢀxꢀ5”ꢀfootprint
•ꢀ Lessꢀthanꢀ1Uꢀhigh
•ꢀ Remoteꢀsense
•ꢀ Terminalꢀblockꢀoptionꢀ(-T)
•ꢀ Built-inꢀEMIꢀfilter
•ꢀ Lowꢀoutputꢀripple
Inputꢀrange:
Frequency:
Inrushꢀcurrent:
Inputꢀcurrent:
Efficiency:
85ꢀ-ꢀ264ꢀVAC;ꢀ120ꢀ-ꢀ300ꢀVDC
47ꢀ-ꢀ440ꢀHz
<ꢀ18ꢀAꢀpeakꢀ@ꢀ115ꢀVAC;ꢀ<ꢀ36ꢀAꢀpeakꢀ@ꢀ230ꢀVAC,ꢀcoldꢀstartꢀ@ꢀ25ꢀ°C
1ꢀAꢀmax.ꢀ(RMS)ꢀ@ꢀ115ꢀVAC
70% typical at full load
EMIꢀfilter:
FCCꢀClassꢀBꢀconducted;ꢀCISPRꢀ22ꢀClassꢀBꢀconducted;
EN55022ꢀClassꢀBꢀconducted;ꢀVDEꢀ0878ꢀPT3ꢀclassꢀBꢀconducted
•ꢀ Adjustableꢀoutput
•ꢀ Overvoltageꢀprotection
•ꢀ Overloadꢀprotection
•ꢀ 110ꢀKHzꢀswitchingꢀfrequency
•ꢀ LPX40ꢀenclosureꢀkitꢀavailableꢀ
<ꢀ0.5ꢀmAꢀ@ꢀ50/60ꢀHz,ꢀ264ꢀVACꢀinput
Safetyꢀgroundꢀ
leakageꢀcurrent:
Output
Maximumꢀpower:
Adjustmentꢀrange:
Hold-upꢀtime:
40ꢀWꢀforꢀconvection;ꢀ55ꢀWꢀwithꢀ30CFMꢀforcedꢀair
-5,ꢀ+10%ꢀminimum
20ꢀmsꢀ@ꢀ40ꢀWꢀload,ꢀ115ꢀVACꢀnominalꢀline
Overloadꢀprotection:
Shortꢀcircuitꢀprotectionꢀonꢀallꢀoutputsꢀ
Caseꢀoverloadꢀprotectedꢀ@ꢀ110-145%ꢀaboveꢀpeakꢀrating
Overvoltageꢀprotection:
Remoteꢀsense:
5ꢀVꢀoutput;ꢀ5.7ꢀtoꢀ6.7ꢀVDC.ꢀOtherꢀoutputsꢀ10%ꢀtoꢀ25%ꢀaboveꢀnominalꢀ
output
Compensatesꢀforꢀ0.5ꢀVꢀleadꢀdropꢀminimumꢀ
Willꢀoperateꢀwithoutꢀremoteꢀsenseꢀconnectedꢀ
Reverseꢀconnectionꢀprotected
Safety
• ULꢀ ꢀꢀꢀꢀUL60950ꢀ
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
• CSAꢀ ꢀꢀꢀꢀCSAꢀ22.2-234ꢀLevelꢀ3ꢀ
ꢀꢀꢀꢀLR53982C
• NEMKOꢀENꢀ60950/EMKO-TUE
ꢀꢀꢀꢀE132002
ꢀ
ꢀ
ꢀ
ꢀ
ꢀꢀꢀꢀP94100375ꢀ(74-sec)203
Certificate and report
• CB
ꢀ
ꢀ
ꢀꢀꢀꢀ1119,ꢀ1125,ꢀ1126,ꢀ1127
• CE Markꢀ(LVD)