Embedded Power for
Business-Critical Continuity
Rev. 04.13.06
LPS40 Series
1 of 3
LPS40 Series
40 Watts
RoHS
Total Power:
40-55 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs:
Single
Electrical Specifications
Input
Special Features
• Universal input
• 3" x 5" footprint
• Less than 1U high
• Remote sense
• Terminal block option (-T)
• Built-in EMI filter
Input range
Frequency
Inrush current
Input current
Efficiency
85-264 VAC; 120-300 VDC
47-440 Hz
<18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C
1A max. (RMS) @ 115VAC
70% typical at full load
EMI filter
FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted; VDE 0878 PT3 class B conducted
• Low output ripple
<0.5 mA @ 50/60 Hz, 264 VAC input
• Adjustable output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety ground
leakage current
Output
Maximum power
Adjustment range
Hold-up time
40W for convection; 55W with 30CFM forced air
-5, +10% minimum
20ms @ 40W load, 115VAC nominal line
Short circuit protection on all outputs
Case overload protected @ 110-145% above peak rating
Overload protection
Overvoltage protection
Remote sense
5V output; 5.7 to 6.7VDC. Other outputs 10% to 25% above
nominal output
Compensates for 0.5 V lead drop minimum
Will operate without remote sense connected
Reverse connection protected
Safety
UL
UL1950 E132002
CSA 22.2-234 Level 3
LR53982C
CSA
NEMKO EN 60950/EMKO-TUE
P94100375 (74-sec) 203
CB
Certificate and report
1119, 1125, 1126, 1127
CE Mark (LVD)