5秒后页面跳转
LK4501-7RD6B2 PDF预览

LK4501-7RD6B2

更新时间: 2024-01-30 17:15:15
品牌 Logo 应用领域
BEL /
页数 文件大小 规格书
28页 1215K
描述
AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02

LK4501-7RD6B2 数据手册

 浏览型号LK4501-7RD6B2的Datasheet PDF文件第2页浏览型号LK4501-7RD6B2的Datasheet PDF文件第3页浏览型号LK4501-7RD6B2的Datasheet PDF文件第4页浏览型号LK4501-7RD6B2的Datasheet PDF文件第5页浏览型号LK4501-7RD6B2的Datasheet PDF文件第6页浏览型号LK4501-7RD6B2的Datasheet PDF文件第7页 
Rugged Environment  
AC-DC Converters >100Watt  
K Series  
150 Watt AC-DC Converters with PFC  
K-Series  
Input to output isolation  
Single output: LK 4000 5.1, 12, 15, 24 V  
Double output: LK 5000 2 × 12, 2 × 15, 2 × 24 V  
Universal input voltage range  
Power factor >0.95, harmonics <IEC/EN 61000-3-2  
Input over- and undervoltage lock-out  
Efficient input filter and built-in surge and transient  
suppression circuitry  
4 kVrms input to output electric strength test  
Fully isolated outputs  
Outputs overload, open- and short-circuit proof  
No derating over entire operating temperature range  
Safety according to IEC/EN 60950  
LGA  
111  
4.4"  
3 U  
C
80  
168  
6.6"  
3.2"  
16 TE  
Summary  
The K 4000/5000-series of AC-DC converters represents a  
flexible range of power supplies for use in advanced elec-  
tronic systems. Features include full power factor correc-  
tion, high efficiency, high reliability, low output voltage noise  
and excellent dynamic response to load/line changes.  
IEC/EN 60950 and have been approved by the safety  
agencies LGA (Germany) and UL (USA). The UL Mark for  
Canada has been officially recognized by regulatory au-  
thorities in provinces across Canada.  
The case design allows operation at nominal load up to  
71°C in a free air ambient temperature. If forced cooling is  
provided, the ambient temperature may exceed 71°C but  
the case temperature must remain below 95°C under all  
conditions.  
The converter inputs are protected against surges and tran-  
sients occurring at the source lines. An input over- and  
undervoltage lock-out circuitry disables the outputs if the  
input voltage is outside the specified ranges. Inrush current  
limitation is included preventing circuit breakers and fuses  
from being damaged at switch-on.  
A temperature sensor generates an inhibit signal which  
disables the outputs if the case temperature TC exceeds  
the limit. The outputs are automatically re-enabled when  
the temperature drops below the limit.  
All outputs are overload, open- and short-circuit proof and  
are protected against overvoltages by means of a built-in  
suppressor diode. The outputs can be inhibited by a logic  
signal applied to the connector pin 18 (i). If the inhibit func-  
tion is not used pin 18 must be connected with pin 14 to en-  
able the outputs.  
Various options are available to adapt the converters to in-  
dividual applications.  
The modules may either be plugged into 19 inch rack sys-  
tems according to DIN 41494, or be chassis mounted.  
LED indicators display the status of the converter and allow  
visual monitoring of the system at any time.  
Important: These products are intended to replace the  
LK 1000 and LK 2000 in order to comply with IEC/EN  
61000-3-2.  
Full input to output, input to case, output to case and output  
to output isolation is provided. The modules are designed  
and built according to the international safety standards  
Table of Contents  
Page  
Page  
Summary.......................................................................... 1  
Type Survey and Key Data .............................................. 2  
Type Key .......................................................................... 2  
Functional Description...................................................... 3  
Electrical Input Data ......................................................... 4  
Electrical Output Data ...................................................... 6  
Auxiliary Functions ......................................................... 12  
Electromagnetic Compatibility (EMC) ............................ 16  
Immunity to Environmental Conditions........................... 17  
Mechanical Data ............................................................ 18  
Safety and Installation Instructions ................................ 19  
Description of Options.................................................... 22  
Accessories .................................................................... 28  
Edition 4/4.99  
1/28  
MELCHER  
The Power Partners.  

与LK4501-7RD6B2相关器件

型号 品牌 获取价格 描述 数据表
LK4501-7RD6T BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
LK4501-7RD6TB2 BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
LK4501-7RD7 BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
LK4501-7RD7B1 BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
LK4501-7RD7T BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
LK4501-7RD7TB1 BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
LK4501-7RD8 BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
LK4501-7RD8B2 BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
LK4501-7RD8T BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
LK4501-7RD8TB1 BEL

获取价格

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02