5秒后页面跳转
KURE-41MD-R/Q PDF预览

KURE-41MD-R/Q

更新时间: 2024-11-28 02:06:59
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
4页 139K
描述
Plug-in Signal Conditioners K-UNIT

KURE-41MD-R/Q 数据手册

 浏览型号KURE-41MD-R/Q的Datasheet PDF文件第2页浏览型号KURE-41MD-R/Q的Datasheet PDF文件第3页浏览型号KURE-41MD-R/Q的Datasheet PDF文件第4页 
MODEL: KURE  
6: 220 V / 380 V / 5 A AC  
7: 110 V / 190 V / 1 A AC  
8: 110 V / 190 V / 5 A AC  
Plug-in Signal Conditioners K-UNIT  
VAR TRANSDUCER  
(for 3-phase / 4-wire)  
[2] OUTPUT SIGNAL POLARITY  
P: Negative in lag, positive in lead  
Functions & Features  
• Providing a DC output signal in proportion to AC reactive  
M: Negative in lead, positive in lag  
power  
• DC output containing little ripple is ideal for computer  
input  
[3] OUTPUT  
Current  
• "Time division multiplication" method accepts distorted  
waveforms  
A: 4 – 20 mA DC (Load resistance 600 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1200 Ω max.)  
C: 1 – 5 mA DC (Load resistance 2400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 600 Ω max.)  
E: 0 – 16 mA DC (Load resistance 750 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1200 Ω max.)  
G: 0 – 1 mA DC (Load resistance 12 kΩ max.)  
GW: -1 – +1 mA DC (Load resistance 10 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
• Isolation up to 2000 V AC  
• High-density mounting  
Typical Applications  
• Centralized monitoring and control of power management  
system in a manufacturing facility or building  
72  
(2.83)  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
1W: -10 – +10 mV DC (Load resistance 10 kΩ min.)  
2W: -100 – +100 mV DC (Load resistance 100 kΩ min.)  
3W: -1 – +1 V DC (Load resistance 1000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
80  
(3.15)  
132  
(5.20)  
mm (inch)  
MODEL: KURE–4[1][2][3]–[4][5]  
ORDERING INFORMATION  
• Code number: KURE-4[1][2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. KURE-41PA-C/Q)  
[4] AUXILIARY POWER SUPPLY  
AC Power  
• Calibration range (e.g. lag 1000 – 0 – lead 1000 var)  
• VT ratio, CT ratio (e.g. VT 3300 / 110 V, CT 250 / 5 A)  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
CONFIGURATION  
J: 240 V AC  
4: 3-phase / 4-wire  
DC Power  
R: 24 V DC  
V: 48 V DC  
[1] INPUT (unbalanced load)  
(Voltage must be balanced.)  
1: 63.5 V / 110 V / 5 A AC  
P: 110 V DC  
2: 63.5 V / 110 V / 1 A AC  
[5] OPTIONS  
blank: none  
3: 127 V / 220 V / 1 A AC  
4: 127 V / 220 V / 5 A AC  
/Q: With options (specify the specification)  
5: 220 V / 380 V / 1 A AC  
KURE SPECIFICATIONS  
ES-3657 Rev.2 Page 1/4  
http://www.m-system.co.jp/  

与KURE-41MD-R/Q相关器件

型号 品牌 获取价格 描述 数据表
KURE-41MD-V MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KURE-41MD-V/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KURE-41P1-B MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KURE-41P1-B/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KURE-41P1-C MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KURE-41P1-C/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KURE-41P1-D MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KURE-41P1-D/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KURE-41P1-F MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KURE-41P1-F/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT