5秒后页面跳转
KR-52-S/BL/Q PDF预览

KR-52-S/BL/Q

更新时间: 2024-02-29 18:56:25
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
3页 100K
描述
Plug-in Signal Conditioners K-UNIT

KR-52-S/BL/Q 数据手册

 浏览型号KR-52-S/BL/Q的Datasheet PDF文件第2页浏览型号KR-52-S/BL/Q的Datasheet PDF文件第3页 
MODEL: KR  
Plug-in Signal Conditioners K-UNIT  
[2] OUTPUT  
Current  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
RTD TRANSMITTER  
(CE, non-isolated)  
Functions & Features  
• Accepting direct input from an RTD and providing a  
standard process signal  
• Linearization  
• Burnout protection  
• "Active bridge" circuit containing two constant current  
sources allows large leadwire resistances up to 200 Ω  
• High density mounting  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 3000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
Typical Applications  
• Long distance transmission between the RTD and the  
transmitter  
• Combination with intrinsic safety barriers  
50  
(1.97)  
[3] POWER INPUT  
AC Power  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
80  
(3.15)  
DC Power  
123  
(4.84)  
S: 12 V DC  
mm (inch)  
R: 24 V DC  
[4] OPTIONS (multiple selections)  
Burnout  
MODEL: KR–[1][2]–[3][4]/CE  
blank: Upscale burnout  
ORDERING INFORMATION  
• Code number: KR-[1][2]-[3][4]/CE  
Specify a code from below for each of [1] through [4].  
(e.g. KR-4A-H/BL/CE)  
/BL: Downscale burnout  
Standards & Approvals (must be specified)  
/CE: CE marking  
• Temperature range (e.g. 0 – 500°C)  
• Special output range (For codes Z & 0)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel  
Housing material: Flame-resistant resin (black)  
Isolation: Input or output to power  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
Linearization: Standard  
[1] INPUT RTD (2- or 3-wire)  
1: JPt 100 (JIS'89)  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 50°C, 90°F)  
3: Pt 100 (JIS'89)  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
4: Pt 100 (JIS'97, IEC)  
(Usable range: -200 to +650°C, -328 to +1202°F; min.span: 50°C, 90°F)  
5: Pt 50 Ω (JIS'81)  
(Usable range: -200 to +500°C, -328 to +932°F; min.span: 100°C, 180°F)  
6: Ni 508.4 Ω  
INPUT SPECIFICATIONS  
Maximum leadwire resistance: 200 Ω per wire (3-wire)  
Sensing current: 2 mA  
(Usable range: -50 to +200°C, -58 to +392°F; min.span: 30°C, 54°F)  
0: Specify  
Note: Consult M-System for 2-wire RTD  
KR SPECIFICATIONS  
ES-3536-CE Rev.9 Page 1/3  
https://www.m-system.co.jp/  

与KR-52-S/BL/Q相关器件

型号 品牌 获取价格 描述 数据表
KR-52-S/CE MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KR-52-S/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KR52S018F KEC

获取价格

BIPOLAR LINEAR INTEGRATED CIRCUIT
KR52S018M KEC

获取价格

BIPOLAR LINEAR INTEGRATED CIRCUIT
KR52S025F KEC

获取价格

BIPOLAR LINEAR INTEGRATED CIRCUIT
KR52S025M KEC

获取价格

BIPOLAR LINEAR INTEGRATED CIRCUIT
KR52S026F KEC

获取价格

BIPOLAR LINEAR INTEGRATED CIRCUIT
KR52S026M KEC

获取价格

BIPOLAR LINEAR INTEGRATED CIRCUIT
KR52S027F KEC

获取价格

BIPOLAR LINEAR INTEGRATED CIRCUIT
KR52S027M KEC

获取价格

BIPOLAR LINEAR INTEGRATED CIRCUIT