5秒后页面跳转
KDY-A-S PDF预览

KDY-A-S

更新时间: 2024-11-19 02:43:47
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
3页 100K
描述
Plug-in Signal Conditioners K-UNIT

KDY-A-S 数据手册

 浏览型号KDY-A-S的Datasheet PDF文件第2页浏览型号KDY-A-S的Datasheet PDF文件第3页 
MODEL: KDY  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
Plug-in Signal Conditioners K-UNIT  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 100 Ω min.)  
4: 0 – 10 V DC (Load resistance 1000 Ω min.)  
5: 0 – 5 V DC (Load resistance 500 Ω min.)  
6: 1 – 5 V DC (Load resistance 500 Ω min.)  
4W: -10 – +10 V DC (Load resistance 2000 Ω min.)  
5W: -5 – +5 V DC (Load resistance 1000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
CURRENT LOOP SUPPLY  
(isolated)  
Functions & Features  
• Powering a 4 – 20 mA DC current loop  
• Shortcircuit protection  
• Applicable to smart transmitters  
• Isolation up to 2000 V AC  
• High-density mounting  
[2] POWER INPUT  
AC Power  
Typical Applications  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
• Various 2-wire transmitters  
• Isolation application (4 – 20 mA input)  
50  
(1.97)  
80  
(3.15)  
DC Power  
S: 12 V DC  
R: 24 V DC  
123  
(4.84)  
mm (inch)  
[3] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
MODEL: KDY–[1]–[2][3]  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
ORDERING INFORMATION  
• Code number: KDY-[1]-[2][3]  
Specify a code from below for each of [1] through [3].  
(e.g. KDY-A-B/Q)  
/C02: Polyurethane coating  
/C03: Rubber coating  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
INPUT  
Current  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
4 – 20 mA DC (Input resistance 250 Ω)  
[1] OUTPUT  
Current  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
SUPPLY OUTPUT  
Output voltage: 24 – 28 V DC with no load  
Current rating: ≤ 22 mA DC  
Shortcircuit Protection  
KDY SPECIFICATIONS  
ES-3596 Rev.9 Page 1/3  
http://www.m-system.co.jp/  

与KDY-A-S相关器件

型号 品牌 获取价格 描述 数据表
KDY-A-S/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KDY-B- MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KDY-B-/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KDY-B-B MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KDY-B-B/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KDY-B-C MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KDY-B-C/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KDY-B-D MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KDY-B-D/Q MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT
KDY-B-F MSYSTEM

获取价格

Plug-in Signal Conditioners K-UNIT