40 Watts
xppower.com
JTL Series
•
•
•
•
•
•
•
4:1 Input Range
High Power Density
Single and Dual Outputs
High Efficiency ꢀ Up to 92%
Remote On/Off
1600 VDC Isolation
3 Year Warranty
Specification
Input
General
Input Voltage Range
Input Current
Input Reflected
Ripple Current
• 24 V (9-36 VDC), 48 V (18-75 VDC)
• See table
• 20 mA pk-pk through 12 µH inductor
Efficiency
Isolation
• See table
• 1600 VDC Input to Output
1600 VDC Input to Case
1600 VDC Output to Case
Input Reverse
Voltage Protection
Undervoltage Lockout • 24 V models: ON 8.6 V, OFF 7.9 V typical
• None
Isolation Capacitance • 2500 pF max
Switching Frequency
Power Density
MTBF
• 270 kHz, typical
• 25 W/in
• 150 kHrs min to MIL-HDBK-217F
at 25 °C, GB
3
48 V models: ON 17.8 V, OFF 16 V typical
• Pi network
• 24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
Input Filter
Input Surge
Environmental
Output
Operating Temperature • -40 °C to +85 °C, see derating curve
Output Voltage
Output Voltage Trim
Minimum Load
Line Regulation
Load Regulation
• See table
Case Temperature
Cooling
• +105 °C max
• Convection-cooled
• 5-95% RH, non-condensing
•
10%
• No minimum load required
• 0.5% max
Operating Humidity
Storage Temperature • -40 °C to +125 °C
• Single output models: 0.5% max
Dual output models: 1% max
balanced outputs
EMC & Safety
Cross Regulation
Setpoint Accuracy
Start Up Time
•
•
5% for dual outputs (see note 2)
1%
Emissions
• EN55022, class A conducted and
radiated with external components
• EN61000-4-2, level 3, Perf Criteria A
• EN61000-4-4, level 3, Perf Criteria A
(see note 4)
• EN61000-4-5, installation class 2,
Perf Criteria A (see note 4)
• EN61000-4-6, 3 Vrms, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A
• 25 ms typical
ESD Immunity
EFT/Burst
Ripple & Noise
• 50 mV pk-pk max for 3.3 V & 5 V models,
75 mV pk-pk max for other single output
models, 150 mV pk-pk max for dual output
models, 20 MHz bandwidth, (see note 3)
• 3% max deviation, recovery to within
1% in <250 µs for a 25% load change
Surge
Transient Response
Conducted Immunity
Magnetic Fields
Temperature
Coefficient
• 0.02%/°C
Overvoltage Protection • 3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
12 V models: 15 V typical
15 V models: 18 V typical
12 V models: 15 V typical
15 V models: 18 V typical
Overload Protection
• >130% of full load
Short Circuit Protection • Trip & restart (Hiccup mode), auto recovery
Remote On/Off
• On = Logic High (>3.0) or Open
Off = Logic Low (<1.2 V) or short pin 2 to 3
Max Capacitive Load
• See table