MODEL: JFK  
Plug-in Signal Conditioners M-UNIT  
[2] OUTPUT  
Current  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
3-input MATH FUNCTION MODULE  
(field-programmable)  
Functions & Features  
• Providing temperature and pressure compensation for a  
gas flow, and other arithmetic operations  
• Microprocessor based  
• Equation and parameters  
selectable on site via hand-held programmer PU-2x  
• Loop testing  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Isolation up to 2000 V AC  
• High-density mounting  
Typical Applications  
• Various flowmeters  
• Adding three flows  
• Calculating average temperature  
50  
(1.97)  
[3] POWER INPUT  
AC Power  
80  
(3.15)  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
136  
(5.35)  
mm (inch)  
MODEL: JFK–[1][2]–[3][4]  
DC Power  
S: 12 V DC  
R: 24 V DC  
ORDERING INFORMATION  
• Code number: JFK-[1][2]-[3][4]  
V: 48 V DC  
Specify a code from below for each of [1] through [4].  
(e.g. JFK-6A-B/2/Q)  
[4] OPTIONS (multiple selections)  
Equation (Refer to the EQUATION table)  
/1: Temp. & pressure compensation for DP flowmeter  
(ideal gas)  
• Special output ranges (For codes Z & 0)  
• Parameters  
Use Ordering Information Sheet (No. ESU-1681) to specify  
parameters. Default setting will be used if not otherwise  
specified.  
/2: Addition/subtraction  
/3: Multiplication  
(K0  
= 1, K  
1
= 1, K  
2
= 1, K  
3
= 1, A  
0
= 0 %, A  
1
= 0 %, A = 0 %,  
2
/4: Multiplication/division  
A3  
= 0 %)  
/5: Multiplication/division  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
/6: Addition/multiplication  
/7: Addition/division  
/8: Addition/division  
/9: Addition/multiplication  
/10: Addition/division  
[1] INPUT  
Current  
Other Options  
A: 4 – 20 mA DC (Input resistance 100 Ω)  
Voltage  
blank: none  
/Q: Option other than the above (specify the specification)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
JFK SPECIFICATIONS  
ES-1681 Rev.7 Page 1/3  
http://www.m-system.co.jp/  

与JFK-60-G/4相关器件

型号 品牌 获取价格 描述 数据表
JFK-60-G/5 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JFK-60-G/6 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JFK-60-G/7 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JFK-60-G/8 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JFK-60-G/9 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JFK-60-H MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JFK-60-H/1 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JFK-60-H/10 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JFK-60-H/2 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT
JFK-60-H/3 MSYSTEM

获取价格

Plug-in Signal Conditioners M-UNIT